Descargar Imprimir esta página

Jotul Cube Serie Manual De Instrucciones página 11

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Fig. 15
1
1.
Adjust the height of the insert. It shall be a gap of 10 mm
between the edge of the door and the upper edge of the
opening in the cage (Fig. 15.1).
2.
Adjust the insert position so that the door is 13 mm outside
the cage (Fig. 15.2).
Fig. 16
3
13 mm
2
2
4
Mount the side profiles (Fig. 16.1) with 3 screws (Fig. 16.2).
1.
Mount and adjust the front profile (Fig. 16.3) with 2 screws
2.
(Fig. 16.4).
Fig. 17
2
Mount the bracket (Fig. 17.1) on the back panel.
1.
Mount the heat shield (Fig. 17.2) to the bracket.
2.
N.B. It is extremely important that the heat shield is mounted
correctly. If it is mounted wrong the back wall will be exposed to
higher temperature. Then the product has to be placed further
away from the wall.
Fig. 18
1
Jøtul I 200 FL
Jøtul I 500 FL
Jøtul I 530 FL
Jøtul I 400 FL
1.
Mount the bracket (Fig. 18.2) between the sides and the
screws of the smoke bell (Fig. 18.4), and from the front to the
smoke bell. (The illustration shows this done on Jøtul I 400 FL)
ENGLISH
1
2
3
1
4
11

Publicidad

loading

Este manual también es adecuado para:

Cube 200Cube 400Cube 500Cube 530