RIB PRINCE 24V Manual Del Usuario página 28

Operador para cancelas batiente
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

G G
B B
B
ATTERY CHARGE CARD
The time needed to completely charge the 12Vdc 2,2Ah batteries (n° 2
batteries connected in series, optional cod. ACG9515), upon first
installation, is 24 hours, with a charging current of 0.03A.
POWER SUPPLY GATE OPEN INDICATOR AND STATE OF
BATTERY (COM-SIGNAL)
This indicator, in addition to signalling that the gate is open, emits 2
brief flashes followed by a pause of 2 seconds when the gate is closed
and there is no power supply, indicating that it is functioning with the
battery.
Functioning of the gate is guaranteed up to a charging level of
approximately 20V, following which the gate blocks and the indicator
flashes continuously to signal that the battery is low.
Only when voltage returns will the indicator go out and all the controls
be restored (obviously the battery will only recharge when there is
voltage).
N.B.: If you overdo the leds, the board's circuit will suffer from this, with
a possible block of the operations.
FUNCTIONING IN A BLACKOUT (WITH BATTERIES)
If batteries are connected to the control unit, when there is a power cut
the functioning of the gate is guaranteed up to a charging level of
approximately 20V, following which a signal is sent by the recharge card
to the control unit which blocks the gate and makes the battery signal
light flash.
Once voltage returns we recommend that the gate be fully opened.
Allow the gate to close by itself with automatic closure or wait for the
flashing light to stop before giving the command to close.
This operation will allow the gate to realign itself. In fact, if during the
blackout the motors were released and moved from the normal closing
position, the first manoeuvre when the power supply returns must be
complete.
During this phase the safety devices are active.
B
ATTERY
Battery 2,2Ah 12V
B
LOCK
BLOCK KEY SELECTOR FOR WALL-INSTALLATION code ACG1053
BLOCK KEY SELECTOR TO BUILD-IN
F
IT SLIM
PHOTOCELLS for the wall-installation
FIT SLIM photocells have synchronism function in AC current and
ranges of 20m.
You can fit many couples close together thanks to the synchronising
circuit.
Add the SYNCRO TRANSMITTER TX SLIM SYNCRO code ACG8029
for more than 2 photocells couples (up to 4).
M
ECHANICAL BOLT
code ACG4648
For 2-leaf gates to latch closed gate to the ground.
E
LECTRIC LOCK
Horizontal lock - right external view - 12Vac
Horizontal lock - left external view - 12Vac
code ACG9515
Vertical lock - 12Vac
code ACG1048
code ACG8032
code ACG5000
code ACG8660
code ACG8670
code ACG8650

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Prince 24v plusAa14031Aa14030Aa25041

Tabla de contenido