Technical Data - Grohe MintaTouch 31 358 Manual De Instrucciones

Ocultar thumbs Ver también para MintaTouch 31 358:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 10
GB
GB
Safety notes
• Installation is only permitted in frost-free rooms.
• The plug-in connectors must not be directly or indirectly
sprayed with water when cleaning.
Application
Can be used in conjunction with:
• Pressurised storage heaters
• Thermally-controlled instantaneous heaters
• Hydraulically-controlled instantaneous heaters
Operation with unpressurised storage heaters (displacement
water heaters) is not possible.

Technical data

• Flow pressure:
– min.
– recommended
• Operating pressure
• Test pressure
If static pressures exceed 0.5 MPa, a pressure-reducing valve
must be installed.
Avoid major pressure differences between hot and cold water
supply.
• Flow rate at 0.3 MPa flow pressure
- Shower:
- Aerator:
• Hot water supply temperature:
Recommended (energy saving):
• Ambient temperature:
• Relative air humidity:
• Voltage supply:
• Power consumption:
• Automatic safety shut-off after touch:
• 3 water pulses indicates discharged battery.
• Control type of protection:
• Water connection
Approval and conformity
This product conforms to the requirements of the
relevant EU guidelines.
The conformity declarations can be obtained from the following
address:
GROHE Deutschland Vertriebs GmbH
Zur Porta 9
D-32457 Porta Westfalica
Installation
Refer to the hose lengths and installation dimensions on fold-
out page I.
Caution: The control should be easily accessible to trigger
cleaning mode.
Flush pipes thoroughly before and after installation
(observe EN 806).
3
0.05 MPa
0.1 – 0.5 MPa
max. 1,0 MPa
1,6 MPa
approx. 9 l/min
approx. 11 l/min
max. 80 °C
60 °C
4 – 40 °C
max. 80%
6V lithium battery (type CR-P2)
1,4 W
60 s
IP 44
cold - right (T-connector)
hot - left
Install and connect fitting, see fold-out page II, Fig. [1] to [7].
Caution: T-connector must be connected on the cold water
supply, see Fig. [6].
Install holder and control, see Fig. [8] and [9].
Insert battery and connect solenoid valve to control, see
Fig. [10] to [14].
When using metal sinks, the sink must be connected to
the control using the enclosed cable, see fold-out page III,
Fig. [15].
Open hot and cold water supply and check that
connections are watertight.
Operation/commissioning
To avoid water damage, ensure the spout is
always positioned over the sink and ensure
free draining.
Operation, see fold-out page III, Fig. [16].
By touching the gray areas with your hand, cold water can be
drawn without operating the lever
Caution: Triggering only through skin contact.
The spout can be swivelled by the white mouthpiece without
triggering the fitting.
31 358: Shower jet diverter, see Fig. [17].
Flow rate limitation, see Fig. [18] and [19].
Cleaning mode, see Fig. [20].
Cleaning mode is activated by pressing the AQUA STOP
button.
• Confirmation by a water pulse and 1 x flashing of the
indicator lamp in the control.
• In cleaning mode, the indicator lamp flashes 2 x.
• Elapse of cleaning mode after 2 minutes.
Adjusting the sensitivity, see Fig. [20].
The sensitivity of the triggering varies depending on the
ambient temperature and humidity. The sensitivity can be
adjusted in 5 steps. The control step 3 is factory preset.
By pressing the AQUA STOP button for at least 10 seconds,
the menu is activated and the indicator lamp flashes 1x.
• The last saved value will then be shown by flashing, e. g. 3x
for step 3.
• Each additional pressing increases the sensitivity by one
step.
• If no pressing is performed, the indicator light flashes 1x and
the menu is exited. The last set value is stored.

Publicidad