Safety Instructions

Please read and follow all safety
instructions and warnings.
Children and adults should be alerted to the
hazards of high surface temperatures and should
stay away to avoid burns or clothing ignition.
Young children should be carefully supervised when they
are in the area of the heater. Keep out of reach of children.
Clothing or other flammable materials should not be
hung from the heater, or placed on or near the heater.
Note:
Some or all of the following required safety instructions
for propane powered devices may apply to your Liberty.
Allow trap to cool for 5 minutes before re-starting.
Warning:
Improper installation, adjustment, alteration,
service or maintenance can cause injury or property damage.
Read the installation, operating and maintenance instructions
thoroughly before installing or servicing the Liberty.
Caution:
The gas pressure regulator provided with this
appliance must be used. This regulator is set for an outlet pressure
of 11.0 in. Water Column. The minimum inlet gas supply pressure is
11.0 in. Water Column from regulator.
This unit is not intended to be installed in or on recreational vehicles and/or boats.
The gas supply must be turned off at the LP-Gas supply cylinder when
this appliance is not in use.
The installation must conform with local codes or, in the absence of
local codes, with the National Fuel Gas Code, ANSI Z223. 1-1998 for US
and with the CAN1-B149 for Canada.
To test for a gas leak, place soapy water around the connector,
regulator, and gas hose assembly. If bubbles appear, there is a gas leak.
Inspect the hose before each use of the unit. If it is evident there is
excessive abrasion or wear, or the hose is cut, it must be replaced prior
to the unit being put into operation. The replacement hose shall be that
specified by the manufacturer.
The Liberty is equipped with an internal hot surface igniter. Failure to
follow starting procedure will result in the trap not starting.
Installation and repair should be done by a qualified service person
(find service centers on www.mosquitomagnet.com). The heater should
be inspected before use and at least annually by a qualified service
person. More frequent cleaning may be required as necessary. It is
imperative that the control compartment, burners, and circulating air
passageways of the heater be kept clean.
3
• Maintain adequate clearances of 20"–24" around air openings into
the combustion chamber, clearances from combustible material,
provisions for accessibility and for combustion and ventilating air
supply. Keep the Liberty area clear and free from combustible
materials, gasoline, and other flammable vapors and liquids. The
appliance is not to be used in locations where flammable vapor or
explosive dust is likely to exist.
• Do not obstruct the flow of combustion and ventilation air.
• Keep the ventilating openings of the cylinder enclosure free and clear from debris.
• Clean the Liberty with a water damp cloth, if necessary.
• A maximum of a 20 lb. LP-Gas cylinder shall be used.
• The LP-Gas cylinder must be provided with a shut-off valve terminating
in an LP-Gas supply cylinder valve outlet specified for Connection No.
510 in the Standard for Compressed Gas Cylinder Valve Outlet and Inlet
Connections, ANSI/CGA-V-1-1977.
• The LP-Gas cylinder supply system must be arranged for vapor withdrawal
and the cylinder must include a collar to protect the cylinder valve.
• The LP-Gas cylinder used shall be constructed and marked in accordance
with the specifications for LP-Gas cylinders of the U.S. Department of
Transportation (DOT) or The National Standard of Canada CAN/CSA-B339.
• The Liberty shall be used outdoors only in a well ventilated space and
shall not be used in a building, garage, or any other enclosed area.
• The LP-Gas cylinder must be disconnected and removed from the
appliance, if the appliance is stored indoors.
• LP-Gas cylinders must be stored outdoors in a well-ventilated area out
of reach of children.
• Disconnected cylinders must have threaded valve plugs tightly installed
and must not be stored in a building, garage, or any other enclosed area.
• The pressure regulator and hose assembly supplied with this appliance
must be used for connection to the LP-Gas cylinder. Replacement pressure
regulators and hose assemblies must be specified by the manufacturer.
• Avoid improper use of extension cords. Keep connections away from
moisture and avoid damage to the cord.
• If the supply cord is damaged, it must be replaced by the manufacturer or
its service agent or a similarly qualified person in order to avoid hazard.
Please contact Customer Care
if you have any questions at:
1-800-953-5737
or visit www.mosquitomagnet.com
Warning:
SHOCK! An electric shock hazard may exist if
water from a garden hose is directed at the Mosquito
Magnet. Route the power cord in the safest possible manner
to avoid personal injury.

Principal Parts

Self-Contained
Liberty
Base Frame (1)
Wheels (2)

Parts Included

Mosquito Magnet
®
Octenol Biting
Quick-Clear Adapter
Insect Attractant
EPA Reg. No. 72563-1 (Short-Range Attractant)
Bug Bag
Already Installed
Power Head (1)
Trumpet (1)
Upper Legs (2)
Lower Legs (2)
Feet (2)
Power Cord
10 Metal Power Cord
Burying Clips
One (1) Bag of Hardware
is also included.
4

Publicidad

Tabla de contenido
loading

Productos relacionados para Mosquito Magnet Liberty

Tabla de contenido