Easy Quick-Clear Valve
Important: Extinguish all smoking materials prior
to use of Easy Quick-Clear Valve. Do not stand directly
behind the Quick-Clear cartridge during operation.
Use of PROTECTIVE eyewear is recommended.
Quick-Clear is recommended for regular maintenance
to remove built-up contaminants but is not required for
operation of your Liberty.
Recommended for use at first tank change, and every
second tank change thereafter. Also recommended for use
before seasonal storage to avoid build up of contaminants
during the off-season. Instructions for "Easy Quick-Clear
Valve" maintenance procedure shall be provided on a label
attached to appliance where easily visible by user.
The Easy Quick-Clear Valve is a gold, threaded knob located
on the back of your trap. It should be used with the adapter
included with your Liberty, and a threaded Quick-Clear
cartridge available on our website at: www.mosquitomagnet.com
or at your local Mosquito Magnet
®
Dealer.
1. Shut down your Liberty. Let fan run until it stops.
(About 5 minutes).
2. Close the propane tank valve by turning to the "OFF"
position. (Turn the tank valve clockwise).
3. Remove the protective cap from Easy Quick-Clear
valve on your trap.
4. Hand-screw the Quick-Clear adapter on to Quick-Clear
valve, until finger tight.
5. Hand-screw the Quick-Clear cartridge into the Quick-
Clear adapter clockwise until hand tight while holding
the adapter in place. Important: Do not over-tighten.
6. While holding the adapter in place slowly unscrew
Quick-Clear cartridge up to 1/4 turn only in counter
clockwise direction from the Quick-Clear adapter only.
The strong flow of compressed air lasts approximately
45 seconds. Be sure to allow Quick-Clear cartridge to
run out completely. (Hissing will stop when cylinder is
empty. Quick-Clear cartridge will be cold to the touch)
7. Unscrew the Quick-Clear cartridge to remove. Discard empty
Quick-Clear cartridge after use, it is not reusable or refillable.
8. Unscrew the Quick-Clear adapter to remove.
Use caution when removing Quick-Clear adapter and
cartridge, as some compressed air may come out at this time.
Remember to keep the Quick-Clear adapter for future use.
9. Replace Easy Quick-Clear Valve protective cap, and
proceed with normal start up of your Liberty. If use of
Easy Quick-Clear valve feature does not resolve
starting trouble, contact Customer Care 1-800-953-5737.
13
Step 4
First hand-screw the Quick-Clear adapter onto the valve.
Step 5
While holding the adapter in place, screw the Quick-Clear
cartridge into Quick-Clear adapter.
Step 6
To start cleaning process, while holding Quick-Clear
Adapter in place, unscrew the Quick-Clear cartridge
1/4 Turn Only.
Step 7
Unscrew the Quick-Clear cartridge first, then unscrew Quick-
Clear adapter and discard the spent Quick-Clear cartridge.
Remember to keep the Quick-Clear adapter for future use.
Troubleshooting
Problem
Possible Cause
1. Is the propane tank empty?
2. If propane tank is new, it may have
air blockage, has it been purged?
Your Mosquito Magnet
®
3. If tank has been opened too quickly, security
won't start
check valve may have triggered.
4. Is the power cord plugged in?
5. Is there a loose connection?
6. The tank regulator isn't fully engaged.
7. Propane tank may be empty or need
to be purged.
The Mosquito Magnet
won't stay running
8. Regulator is not fully engaged
9. Fuel line may be blocked by propane
contaminents.
10. Insects may not be out yet.
11. Trap improperly placed.
Low or no catch
12. Biting insects reproductive cycles have not
yet been broken.
Customer Care **Please have your serial number, date of purchase & model type available**
All of us at Woodstream
®
Corporation want you to get complete satisfaction from your Liberty. Should you have any problems you cannot
resolve, simply call one of our trained Customer Service Representatives at 1-800-953-5737 or visit www.mosquitomagnet.com.
We will help you get up and running.
Solutions
1. Weigh tank and check against "empty" weight
written on tank.
2. Bring tank to filling location. Air may be in
fuel line. Ask for tank to be purged.
Hint: If you have another propane powered device
operating on a standard, 20 lb propane tank, try
hooking that tank up to the Liberty to verify that
the issue is with your tank.
3. Disconnect the regulator from the tank and
reconnect. Then open the regulator valve slowly.
4. Verify all electrical connections. Make sure you are
using the correct power requirements for your unit.
5. Make sure regulator is fully engaged, and propane
tank valve is fully open.
6. Make sure the regulator is fully engaged, and
propane tank valve is fully open.
7. Go through above steps 1, 2 and 3.
8. See tank changing tips on page 12. Hand tighten
the propane tank regulator until slightly snug.
9. Follow Easy Quick-Clear Valve instructions.
See page 13.
10. Verify temperature is consistently above 50˚F (10˚C).
11. Follow steps in the "Trap Placement" section of
your owner' s manual or go to
www.mosquitomagnet.com "Placement" section.
12. Keep trap in constant operation 24 hours/day,
7 days/week for 4-6 weeks to interrupt the
breeding cycle.
14