EN
E-PAK 500
Caution! Risk of equipment damage.
Never operate the unit without a plastic bag.
9.3
Replacing the main filter and filter bags
WARNING!
Always disconnect the supply voltage with the maintenance switch before any service, whether
mechanical or electrical. Always lock the maintenance switch in the off position.
WARNING!
Ensure that there is no vacuum present in the system during service.
WARNING!
Always disconnect the compressed air supply before any service.
WARNING!
Use proper lifting and protective equipment.
9.3.1
Main filter
Replace the whole main filter after approximately 6,000 hours of operation and at least every
3 years.
To replace the main filter:
Remove the main filter according to Figure 16.
1.
Put the old filter in a large plastic bag, or wrap it in plastic foil, see Figure 13.
2.
NOTE!
Install the new main filter.
3.
Caution! Risk of equipment damage.
It is important that no dust, objects or debris are allowed to fall down into the inlet of the side
channel fan.
9.3.2
Individual filter bags
Replacing individual filter bags is possible, but we recommend replacing the whole filter
package, including the filter panel and locking rings, as it is quicker and causes less spreading
of dust.
Individual filter bags which have been damaged may be replaced, see Figure 14. Use a robust
screwdriver to detach the plastic locking ring.
The coiled spring may be kept for use with the new filter bag, but a new locking ring is to be
used to secure the new filter, see Figure 15.
NOTE!
9.4
Fan service
WARNING!
Use proper lifting and protective equipment.
Caution! Risk of equipment damage
It is important that no dust, objects or debris are allowed to fall down into the inlet of the side
channel fan.
32
Risk of electric shock.
Risk of personal injuries.
Risk of personal injuries.
Risk of personal injuries.
Avoid dust spreading.
Never re-use an old locking ring!
Risk of personal injuries.