Planning Your DECT Network
A carefully planned DECT network is a prerequisite for high call quality and
adequate call capacity for all subscribers in all buildings and areas covered by
the PBX.
This is especially true for the successful operation of the COMfortel WS-500M
multi-cell system.
The document "COMfortel WS-500M Site Planning and Measurement Guide,
Instructions Measurement Case" (which you can find in the Internet) contains
information that will make it easier for you to plan your DECT network. It
describes the preparatory work that is necessary for installation and describes
how to take measurements, to enable you to find the best possible position for
your base stations.
You can use the COMfortel WS-500M Measurement Case (not included in the
scope of delivery) to measure the radio coverage and signal quality in your
DECT network.
Wall Mounting
The COMfortel WS-500S/500M is designed to be mounted on a wall.
Important: Note the location requirements. You must first successfully
plan the DECT radio network.
Note: The COMfortel WS-500M that is only used as a DECT Manager
and Integrator in a large installation can be installed anywhere in range of
the local network.
Note: Take a note of the MAC address of the base station on which the
DECT Manager and Integrator are enabled.
COMfortel WS-500S/500M - Instructions V02 08/2019
Initial Commissioning
29