OFA TIME OFF
• Select with the button
• It's possible to adjust OFA time in minutes
CALIBRATION 7/4pH or 465mV
• Select with the button
• It's possible to select 2 points 7 and 4 pH, 1 point only 7pH or function disable; we have 465
mV for the redox function or disabled
MAN TEMPERATURE 25°C (pH measure only)
• Select with the button
• Set the temperature manually (pH measure only)
• Save and escape Program setup with ESC key.
EXIT SAVE
• Select with the button
PRIMING
• Priming Pump Keep Press
1) Input pH or Redox Probe
2) Input Flow Rate (High Voltage 230 Vac)
3) Power Supply 230 Vac 50Hz/60Hz
Code 0000137847
and set with
and set with
and set with
and set with
Save or Not Save
for 3 seconds

Wire Connection:

Rev 1.0
3