The setting of the setpoints determines the polarity of the analogue out-
put function. See "LIMITS" - function switch 1.
Function switches 1-4
1 2 3 4
Switch 1: LIMITS / SETPOINTS
OFF: Output is in the range of 0....2000 mm (programmable).
The analogue output signal is in the range of 150 to 2000 mm.
ON:
Selectable polarity of the analogue output slope:
Positive slope when SP1 < SP2. SP1 defines the zero point (0 V
or 4 mA) and the shortest distance. SP2 defines the final value
(10 V or 20 mA) and the longest distance.
Negative slope when SP2 < SP1. SP1 defines the zero point (0 V
or 4 mA) and the longest distance. SP2 defines the final value
(10 V or 20 mA) and the shortest distance. See the following
drawing.
4, 0, 0, means a setting of 400 mm.
0
9
1
With this setting of the switches to
8
2
3
the left on the front plate, SP1 is set
7
6
4
5
to 400 mm.
C, 5, 5, means a setting of 1255 mm
0
9
1
(hex "C" = decimal "12").
8
2
With this setting of the switches to
7
3
6
4
5
the right on the front plate, SP2 is set
to 1255 mm.
Switch 4, NC / NO
Switch 3, SENSITIVITY LOW / HIGH
Switch 2, HEX / BCD
Switch 1, LIMITS / SETPOINTS