Switching Outputs; Analogue Outputs; Multiplexed Digital Outputs - CARLO GAVAZZI UC EU 80-1 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

synchronized by interconnecting the HLD inputs. All synchronized sen-
sors transmit at the same time.

Switching Outputs

The switching outputs are all PNP, 100 mA and short-circuit protected.
SP1, SP2
Independently adjustable in steps of 1 mm.
Switching hysteresis is fixed to approx. 1%.
Switching characteristic NO or NC can be selected.
ORA
If the analogue output has a positive slope, ORA indicates that no echo
is received or the measured distance has exceeded the analogue
range.
If the output slope is negative, ORA indicates that the distance is in the
dead zone or below the analogue range.
URA
If the analogue output has a positive slope, URA indicates that the
measured distance is in the dead zone or below the analogue range.
If the output slope is negative, URA indicates that no echo is received
or the distance has exceeded the analogue range.

Analogue Outputs

U
Voltage output, 0 - 10 V, R
I
Current output, 4 - 20 mA, R

Multiplexed Digital Outputs

BCD or HEX. 4 data bits and 4 decade strobes NPN, open collector, 3+
V, 20 mA, short-circuit protected.
Timing diagram of the multiplexed digital outputs - see following
drawing.
= 1450 ohm
MIN
= 250 ohm
MAX
7

Publicidad

Tabla de contenido
loading

Tabla de contenido