a. All LED´s are off: NO AC Power:
There is no AC power applied.
b. Green light flashing only: Standby for charging batteries:
Before using, please check following:
a. The clamps are connected to the battery properly.
b. The battery voltage is below 4 volts.
c. The battery is under charge.
c. Green and red light on: Charging battery
BHFB 05 Charger is charging the battery.
d. Yellow light flashing, Green and red LED light on:
Charging the highlydischarged battery takes longer.
After a charging time of 36 hours yellow LED lights up (defective battery)
e. Yellow light on:
Defective battery
f. Green light on, red light flashing:
The battery is already charged at least 75%.
g. Green light on only:
Battery is fully charged and is under maintaining will automatically
adjust the voltage/current relationship to maintain the battery at a
full charge. The battery is ready for a load test or return to serve. If the battery voltage
drops below 12. 8 volts, the charger shifts automatically into charging mode and re-
charges to an OCV of 14.8 volt. If you are interrupting the charging process of a battery
installed in a vehicle, first disconnect the battery cable from the chassis and then the
other battery cable.
Attention! The housing of the appliance is hot during operation, since the housing
parts have a cooling function. This is not a fault of the device !!!
Attention: The BHFB 05 is not suitable for voltage maintenance during diagnosis
/ SERVICE !!! For this purpose, you need a battery charger from the -Berner-BHFL
series !!!
(EN)
a.
?
b.
c.
d.
!
e.
f.
75%
g.
OK