Sensitivity
• adjustable spring tension position
• optional measuring vane available depending on customer sensitivity requirements
Approximate minimum material density (standard measuring vane)
• 100 g/l (6.25 lb/ft
• 200 g/l (12.5 lb/ft
Approximate minimum material density (hinged measuring vane)
• 35 g/l (2.19 lb/ft
• 70 g/l (4.69 lb/ft
Approvals
• FM/
CSA Class II, Div. 1, Group E, F, G, Class III
c
• CSA
Class II, Div. 2, Class III
us
• ATEX II 1/2 D (dust explosion)
• CE
(see product nameplate for approval details)