COMPACT 3.0
Take care not to invert polarities when connecting the unit. If this were to happen, the control plate
will not come on, the unit will not work and irreparable damage will be caused in the compressor
modules.
Centrifugal
blower
wiring communication
Az
Blue
N
Black
R
Red
V
Green
B
White
A
Yellow
Na
Orange
M
Brown
Compressor
electronic
module
2 Compressor
IMPORTANT WARNING!
Electronic
board
Original shot
23
®
Electric wiring
Return
air sensor
Anti-freeze
sensor
Condenser fan
Compressor
electronic
module
1 Compressor
EN