5) Check that the beer tap lever is in the closed (normal) position. Open the main
valve of the CO2 gas cylinder by turning it counterclockwise a few times.
6) Turn the regulator adjust dial to set the pressure to "0.15" (MPa).
7) Open the beer circuit.
Rotary type: Turn the keg coupler handle clockwise until it stops.
Vertical type: Push down the keg coupler handle until it locks in place.
Note: If the cleaning tank is provided with a siphon tube, lay the cleaning tank with the ferrule at the top. If not, lay the
cleaning tank with the ferrule at the bottom.
Keg Coupler Handle
Rotary Type
8) Pull the beer tap lever toward you to pour water out of the liquid nozzle.
9) Check the CO2 gas circuit for gas leaks. If it is leaking, correct the hose connections.
10) Check the beer circuit for water leaks. If it is leaking, correct the hose connections.
11) Keep the beer tap lever in the open position and turn the
regulator adjust dial to set the pressure to "0" (MPa).
12) Close the main valve of the CO2 gas cylinder by turning
it clockwise.
13) When CO2 gas stops coming out of the nozzle, push the
beer tap lever back to the closed position.
8. CHECKS AFTER INSTALLATION
1) Fill the water tank with the specified water. See "II. 2. FILLING WATER TANK".
2) Flush the beer circuit and check for water leaks. See "III. 2. BEER CIRCUIT (DAILY)".
3) Check for proper power supply voltage.
4) Plug in the unit.
* Check that the refrigeration unit and agitator motor start.
(In low temperature conditions, the condenser fan motor may not start until the condenser temperature goes up.)
* After 8 to 13 hours (depending on ambient/water temperature), open the top cover and check that ice is stored in the water
tank.
5) Instruct the user on how to operate the unit.
6) Hand this instruction manual to the user.
9. SOLD OUT SENSOR SETTING ("U07")
Choose among the four modes according to the type of beverage to dispense (e.g. beer, cocktail).
1) Lower the operation panel unit on the desired side.
2) Press and hold the set button on the operation panel to show "U01" on the display.
3) Use the foam button or liquid button to show "U07" on the display.
Vertical Type
Close
CO2 Gas Cylinder
11
Lever
Closed Position
Siphon Tube
Provided
Not provided
Lever
Closed Position
ENGLISH
Open
CO2 Gas Cylinder
Open Position
Bucket