29) Turn the keg coupler clockwise to attach it to the beer keg.
Note: Wash the joint between the keg coupler and beer keg if it is
not clean.
30) Wipe off moisture from the end of the beer tap nozzles. Clean and attach the nozzle caps (accessory).
Note: Always attach the accessory nozzle caps at the end of
dispensing operation or during periods of non-use to prevent entrance of insects or dirt into the beer tap
nozzles.
6. DISASSEMBLY AND CLEANING OF BEER TAP (WEEKLY)
1) Follow the steps 1) to 7) of "2. BEER CIRCUIT (DAILY)".
2) Lift up the operation panel unit slowly until it clicks and locks into place.
3) Turn the union nut clockwise to remove the beer tap.
4) Loosen the cap nut to disassemble the beer tap.
5) Use a neutral dishwashing detergent and the accessory brush to clean inside the beer tap and
valve shaft.
6) Use the accessory brush (S) to clean the two small holes in the beer tap.
7) Soak the bar and cap nut interior in tap water or warm water and shake
them to remove dirt.
8) Rinse the parts thoroughly with tap water.
9) Fit the valve shaft in the original (normal) direction while aligning the holes
in the beer tap and valve shaft (larger hole facing up), and tighten the cap
nut.
Note: Assemble the beer tap correctly, or beer cannot be dispensed
properly.
10) Hold the bottom of the operation panel unit and pull the front handle toward you to unlock. Pull down the operation panel unit
until it stops to cover up the beer tap lever.
Rotary Type
Cap Nut
Valve
Shaft
Nozzle
Cap Nut
Bar
25
ENGLISH
Vertical Type
Nozzle Cap
Loosen
Union Nut
Brush
Brush (S)
Tap Water or
Warm Water