CONTROL PANEL
A - On/off switch.
B - Temperature adjustment.
C - Power indicator light.
D - Diesel level indicator light.
E - Descaler level indicator light.
F - Fault - Maintenance indicator light.
G - Burner lockout indicator light. (If featured).
SIGNALS AND FAULTS DISPLAYED.
Indicator light C): Power is on when the indicator light is on
steady (switch "A" in pos. I); when the indicator light is flashing,
the high pressure washer is in "TSI" status.
Indicator light D): Fuel level; the light on indicates low fuel level.
Indicator light E): Descaler level; the light on indicates low
descaler level.
Indicator light F): Fault and programmed maintenance interval
indicator.
- 2 flashes, Micro-leak alarm.
- 3 flashes, no water alarm.
- 4 flashes, motor thermal protector activated.
- 5 flashes, safety thermostat activated.
Indicator light on steady, 200h programmed maintenance
interval expired. The light will go off following maintenance by
the authorised service centre.
Indicator light G): Burner lockout signal (if featured).
HIGH PRESSURE WASHER SHUTDOWN - POSSI-
BLE FAULTS
1) High pressure washer not used for more than 20 min., high
pressure washer in total stop mode (TSI).
This is signalled by indicator light C) flashing.
2) Low fuel level: the burner shuts down and not hot water is
delivered.
The fault is signalled by indicator light D) on steady.
3) Low descaler level: the descaling system shuts down.
The fault is signalled by indicator light E) on steady.
4) Micro-leaks detected or water nozzle clogged: the high
pressure washer shuts down.
The fault is signalled by indicator light F) flashing.
5) No water: After 3 minutes of operation with no water detected,
the high pressure washer shuts down.
The fault is signalled by indicator light F) flashing.
6) Motor thermal protector activated: the high pressure washer
shuts down.
The fault is signalled by indicator light F) flashing.
7) Safety thermostat activated: the burner shuts down.
The fault is signalled by indicator light F) flashing.
8) The fault is signalled by indicator light F) flashing.
English
The fault is signalled by indicator light G) on steady.
N.B. To reset the fault signals, turn main switch "A" to
pos."0" and then back to pos. "I".