PROBLEM
Espresso runs out
around the edge
of the portafilter
and/or
Portafilter comes
out of the group
head during an
extraction
Issues with the
Auto Start feature
Operation Error
message on the
touch screen
Pumps continue
to operate / Steam
is very wet / Hot
water outlet leaks
Water does not
flow from the
group head
POSSIBLE CAUSE WHAT TO DO
Portafilter not
inserted in the
group head
correctly.
There are coffee
grounds around the
filter basket rim.
Filter basket rim is
wet or underside of
portafilter lugs are
wet. Wet surfaces
reduce the friction
required to hold
the portafilter in
place whilst under
pressure during
an extraction.
Clock not set or
clock is set with
incorrect time.
A major fault
has occurred
and machine
cannot operate.
Using highly
filtered,
demineralized
or distilled water
which is affecting
how the machine
is designed
to function.
Machine has not
reached operating
temperature.
Water tank
is empty.
Water tank
not fully
inserted & locked.
Ensure portafilter is rotated to the right until the
handle is past the center and is securely locked in
place. Rotating past the centre will not damage the
silicone seal.
Clean excess coffee from the rim of the filter basket
after grinding to ensure a proper seal in group head.
Always ensure filter basket and portafilter are dried
thoroughly before filling with coffee, tamping and
inserting into the group head.
Check that the clock and Auto Start time have been
programmed correctly.
Contact Breville Consumer Support.
We recommend using cold, filtered water. We do not
recommend using water with no/low mineral content
such as highly filtered, demineralized or distilled
water. If the problem persists, contact Breville
Consumer Support.
Allow time for the machine to reach
operating temperature.
Fill tank. Prime the system by:
1) Touching the 'Brew' button to run water through
the group head for 30 seconds.
2) Touching 'Hot Water' to run water through the hot
water outlet for 30 seconds.
Push water tank in fully and lock latch closed.
25