3. STARTING THE PUMP

Insert the plug on the power cord in a suitable power socket.
VERTY NOVA 200 – VERTY NOVA 400
Automatic operation (A):
The integrated fl oat switch starts and stops the pump automatically when the indicator (2) is positioned on "A"
(Fig. A).
Manual operation (M):
To start the pump, lift the knob (3) positioning the indicator (2) on "M" (Fig. A). In these conditions the suction
.
level of the pump will be down to 2-3 mm.
In order to check the correct working and clean the fl oat switch open the cover (1) positioning the indicator on
"O" (Fig. A-B).
4. RECOMMENDATIONS
To ensure the proper operation of the pump, it is important to comply with the following recommendations:
• The pump must never be allowed to run dry.
• Never leave the pump in operation when the delivery pipe is clogged
• The pump must only be used when it is immersed in water. If the water runs out, the pump must be stopped
immediately by removing the plug from the power supply.
s
• Pay careful attention when the pump is operated in manual mode.
• The pump must be placed in a stable position inside a collection pit or in the lowest part of the place where it
is installed.
• The recommended dimensions for the pit are:
- 20 cm x 20 cm for models VERTY NOVA 200-VERTY NOVA 400.
r
• It is absolutely essential to prevent any risk of the pump freezing. In the event of freezing temperatures, remove
the pump from the liquid, empty it and keep it in a place where it cannot freeze.
• To avoid the obstruction of the suction side, periodically, it is advisable to make sure that no dirt (leaves, sand,
-
etc.) has been accumulated in the collection pit.
Overload protection
The pump has a thermal overload safety device. In the event of any overheating of the motor, this device au-
tomatically switches off the pump. The cooling time is roughly 15 to 20 minutes, then the pump automatically
comes on again. If the overload cutout is tripped, it is essential to identify and deal with the cause of the overhe-
ating. See Troubleshooting.
g
5. TROUBLESHOOTING
-
Before taking any troubleshooting action, disconnect the pump from the power supply (i.e. remove
the plug from the socket).
If there is any damage to the power cord or pump, any necessary repairs or replacements must be
handled by the manufacturer or his authorized customer support service, or by an equallyqualifi
ed party, in order to prevent all risks.
5