Battery Charger
Battery Charger Operating Instructions
– SPE CBHD1-XR-P-24-13
GENERAL INFORMATION AND WARNINGS
•
When the machine is not supplied with batteries
installed, the battery charger set to Curve #0 for
Crown 130AH batteries.
•
When the machine is supplied with batteries
installed, the battery charger is set by the NSS
factory for the installed batteries.
•
Electronic automatic battery charger with micro-
processor suitable for any battery type.
•
Universal input voltage:100-240 VAC
•
Fully automatic charging cycle with electronic set-
tings; protected against overload, short-circuit at
clamps and reversed polarity.
•
Before starting to charge, make sure the voltage
of the equipment suits the voltage of the battery,
that the charging current suits the capacity of
the battery and that the selected charging curve
(for lead-acid batteries or airtight gel batteries) is
correct for the type of battery to be charged. In
addition, make sure the rated input voltage of the
charger suits the available supply voltage and the
system is equipped with grounding.
•
Pay attention to any remarks of the battery manu-
facturer.
OPERATING PRINCIPAL OF THE CBHD1-XR-P
When powering up the battery charger it will display
either the flashing Red LED or Green LED for 5 sec-
onds while it checks the AC input voltage and the DC
battery voltage and decide whether or not to start the
charging process. Flashing Red LED at start up indi-
cates one of the two WET charging curves. Flashing
Green LED at start up indicates one of the two AGM/
GEL charging curves.If the battery is not connected
to the battery charger or if there is an anomaly, the
Yellow LED will flash.If the result is positive after 1
second, the charging of the battery will start with the
Red LED on.The output relay closes and the current
of the first phase rises slowly until the programmed
nominal value is reached. If the user disconnects the
battey from the battery charger during charging, the
Red, Yello and Green LED's will be on for 1 second.
After that, the battery charger will reset. The progress
of the charging process is shown by three LED's: Red,
Yellow and Green as typical for the battery charger
product range. The Green LED indicates the end of the
charging or the last phase in the case of a deep charg-
ing process. When charging is finished, the relay is
opened to disconnect.
OPERATION INSTRUCTIONS
•
Plug the cord into a socket.
•
The charging cycle progress will be shown by Red,
Yellow and Green LED indicators. At the end of the
charge, when the green indicator is on, unplug the
cord from the socket and operate the machine.
Front label on Battery Charger SPE CBHD1-XR-P
Red LED Yellow LED Green LED
10
CBHD1-XR-P DIP SWITCH LOCATION
The set of 4-dip switches are easy to find (located
under the round rubber plug next to the power cord)
without opening the charger.
Use a small screwdriver to move the dipswitches up
and down.
Battery Charger DIP Settings
Through the set of 4 dipswitches it is possible to
change the charging curve (4 charging curves are
available for Wet and Gel batteries). The set of 4-dip
switches are easy to find (located under the round
rubber plug next to the power cord) without opening
the charger.
DIP1 DIP2 for selection of the Charging Curve
DIP 1 DIP 2 DIP3
ON
ON
N/A
OFF
ON
N/A
ON
OFF
N/A
OFF
OFF
N/A
N/A - DIPSWITCH SETTINGS FOR DIP3 AND DIP4
DO NOT EFFECT CHARGING CURVE
ON
DIP
CHARGING CURVE
4
N/A
0 - Special Curve for
charging CROWN Lead-
Acid (wet) batteries.
SETTING FOR NSS
2392111 - BATTERY,
WET 12V, 115 AMP/HR
6393651 - BATTERY
WET, 12V, 130 AMP/HR
N/A
1 – Curve for charging
AGM SEALED LEAD-
ACID batteries w/float
charge. SETTING FOR
NSS 2392731 AGM BAT-
TERY, 12V, 98AMP/HR,
7696501 AGM BATTERY,
12V, 110AMP/HR
N/A
2 - Curve for charging
typical GEL sealed lead
acid batteries.
N/A
3 - Wet batteries with
float, 3.5A finish.