Automatic cutout AC-P 10 A / 30 mA
Operating instructions
Please be sure to read the instructions for installation
and use before attempting to connect and use this device!
Symbols used
Symbol indicates a possible hazard.
Safety instructions
To protect you from electrical shocks, injury or burns
the following basic safety principles must be observed
when using electrical devices. Please read and follow these
instructions before using the device.
Installation
Ensure that the devices are positioned safely and cannot fall
down or over. Always position the cables to ensure they do
not pose a tripping hazard. Do not expose electrical devices to
rain. Do not operate electrical devices in damp or wet environ-
ments. Do not operate electrical devices close to flammable
liquids or gases. Position the devices so that they are out of
the reach of children.
Protection against an electrical shock
Only operate devices whose casings and cables are undam-
aged. Ensure the cables are installed safely. Do not pull on the
cables.
Use
Do not use electrical devices for purposes other than those
stated by the manufacturer.
Repairs
Do not repair or modify the device. Please contact your dealer
or the Truma Service (see service manual or www.truma.com).
Accessories
Only use accessories and additional devices that are supplied
or recommended by the manufacturer.
Intended use
Automatic cutout with integrated FI-circuit breaker (residual
current-circuit breaker for personal protection) to secure
the 230 V system in the caravan and camper. The device is
designed for installation in caravans, campers and boats.
Switching on "I ON"
0 OFF
0 OFF
Switching off "0 OFF"
I ON
I ON
4
Function test
Press the key (TEST) when the operating voltage is active. The
switch must trigger and the toggle must switch to the position
"0 OFF".
Maintenance
Repeat the function test once a month.
Ensure that the power supply has been disconnected! Discon-
nect the mains plug!
Clean the device with a dry and fluff-free cloth.
Disposal
The device must be disposed of in line with the administrative
regulations of the respective land in which it is used.
National regulations and laws (in Germany, for example,
the Altfahrzeug-Verordnung [old vehicle directive]) must be
observed.
Rated operational voltage
AC voltage 230 V ~, 50 Hz, single-phase
Automatic cutout (rated current)
10 A, 2-pin 1P + N, characteristic B
FI-circuit breaker
30 mA
Ambient temperature
-25 °C to +40 °C
Dimensions / weight
Casing
Length
Width
Height
Weight
I ON
The right to effect technical modifications is reserved!
Troubleshooting
0 OFF
If these measures do not solve the problem, please
contact the Truma Service Centre.
TEST
I ON
I ON
Technical Data
Plastic, painted, vented
135 mm
125 mm
80 mm
500 g
Error
The switch on the device
does not trigger during
testing.
0 OFF
0 OF
Rectification
Replace the device