Alarm Management; Alrm Management - Palazzetti ECOFIRE Corridoio Serie Manual De Instalación, Uso Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

12 ALARM MANAGEMENT

If a malfunction occurs, the stove responds as follows:
1) an audible alarm (beep) is emitted and the display shows the possible cause;
2) pellet feed stops;
 WKH ÀXH JDV H[KDXVW IDQ RSHUDWHV DW PD[LPXP VSHHG
Below is a list of the various alarm messages that may be shown on the display.
As well as the alarm message, the time and date the fault occurred are also displayed.
ALARM
DESCRIPTION
This alarm is activated if the flue gas
FLUE GAS
temperature is too low for correct stove
TEMP.
operation.
This alarm is activated at the end of the
IGNITION
,*1,7,21 VWDJH LI WKH ÀXH JDV WHPSHUDWXUH
FAILED
is too low for correct stove operation..
T h i s a l a r m i s a c t i v a t e d w h e n t h e
temperature inside the stove exceeds the
HIGH TEMP.
set safety values or when the conditions
DUH QRW ULJKW IRU FRUUHFW ÀXH JDV H[KDXVW
and combustion air intake.
This alarm is activated when the conditions
EXHAUST
DUH QRW ULJKW IRU FRUUHFW ÀXH JDV H[KDXVW DQG
ERROR
combustion air intake.
T h i s a l a r m i s a c t i v a t e d w h e n t h e
PELLET TEMP.
temperature in the pellet hopper exceeds
the set safety values.
This alarm is activated when a fault occurs
FLUE FAN
LQ WKH RSHUDWLRQ RI WKH ÀXH JDV H[KDXVW IDQ
This alarm is activated when a fault occurs
PELLET / FLUE
in the operation of the temperature sensors:
PROBE
ÀXH JDV SUREH  SHOOHW SUREH
This alarm is activated in the event of an
BLACK OUT
extended power failure.
In order to start the stove again, operation must be reset as follows.
Standard procedure "Reset alarms"

:DLW XQWLO WKH VWRYH KDV FRROHG GRZQ FRPSOHWHO\ DQG WKH ¿QDO FOHDQLQJ F\FOH KDV HQGHG
2)
Press the
OFF
3)
The display will show the message "Warning empty burn pot".
4)
Empty any residues from the burn pot; the stove will be ready to start again.
Advanced procedure ³5HVHW KLJK WHPSHUDWXUH DODUP´ SHUIRUPHG E\ WKH 6HUYLFH &HQWUH

:DLW XQWLO WKH VWRYH KDV FRROHG GRZQ FRPSOHWHO\ DQG WKH ¿QDO FOHDQLQJ F\FOH KDV HQGHG
2)
Unplug the stove from the power socket.
3)
Unscrew the protection cap from thermostat with manual reset, located at the rear of the
stove.
4)
Press the button on the thermostat to reset the stove, Fig.12.1.
5)
Perform the standard procedure, "Reset alarms", as described above.
,I WKH DODUP SHUVLVWV FKHFN ZKHWKHU WKH VWRYH RU WKH ÀXH UHTXLUH PDLQWHQDQFH
If the alarm occurs twice consecutively, immediately contact a Palazzetti service centre.
If the external thermostat is being used and an alarm is activated, the stove can only be
started again from the control panel.
MANUALE DI INSTALLAZIONE - cod. 00 477 0811 - 01/2013 - Palazzetti - PN - Italy
USE AND & MAINTENANCE
button on the stove's control panel for 5 seconds.
POSSIBLE CAUSE
No pellets in the hopper.
Poor quality pellets (e.g. damp).
No pellets in the hopper
Poor quality pellets (e.g. damp)
Burn pot not positioned correctly or dirty.
Worn door or ash bin or burn pot gaskets.
Power failure when the stove is operating.
Special maintenance required.
Faulty component.
Flue blocked
Door or ash bin open
Flue blocked
Special maintenance required
Worn gaskets
Door or ash bin open
Power failure when the stove is operating.
Special maintenance required.
Faulty component.
Flue gas exhaust fan fault.
Fault on one or both probes.
Extended power failure.
RESET
Standard procedure
"Reset alarms"
Standard procedure
"Reset alarms"
Advanced procedure
"Reset high
temperature alarm"
Standard procedure
"Reset alarms"
Standard procedure
"Reset alarms"
Standard procedure
"Reset alarms"
Standard procedure
"Reset alarms"
Standard procedure
"Reset alarms"
Fig. .1
53/144

Publicidad

Tabla de contenido
loading

Tabla de contenido