CONTACT FIRE OPERATION (CONTACT TRIP)
For contact fire operation, hold the Trigger and depress the Contact Arm against the work surface.
1
2
SINGLE FIRE OPERATION (ANTI-DOUBLE FIRE MECHANISM AND SEQUENTIAL TRIP)
For single fire operation, depress the Contact Arm against the work surface and pull the Trigger. Tool
can not fire a second nail until the Trigger is released and tool can cycle.
2
1
Adjustment Dial
Adjust Spacer
Deeper
Shallow
Trigger Lock Dial
PROCEDURE
q Hold the Trigger.
w Depress the Contact Arm.
PROCEDURE
q Depress the Contact Arm.
w Pull the Trigger.
DRIVING DEPTH ADJUSTMENT DIAL
WARNING:
ALWAYS disconnect air supply before adjustment dial.
q With air pressure set, drive nails into a representative material sample to determine if
adjustment is necessary.
w If adjustment is required, disconnect air supply.
e Refer to the mark on the Adjust Spacer for direction to turn the adjustment dial.
r Reconnect air supply.
TRIGGER LOCK MECHANISM
The tool is equipped with a Trigger Lock Mechanism. Push and rotate Trigger Lock
Dial from the LOCK to the UNLOCK position before driving nails.
Trigger
Deeper
13
Shallow