To conduct a simulation test:
Switch the UPS on and wait for the "AC normal" indicator to light up. Then unplug the UPS from the AC outlet to
simulate a power failure.
When the failure occurs, power is immediately supplied to your equipment from the UPS battery. The alarm will
beep once every 10 seconds, reminding you that your equipment is running on a limited power source.
During power failure, manually save and close the files you are currently working on. Then, switch the UPS off to
save the battery power for additional testing and usage. If the utility power is not restored, the alarm will change to
rapid beeps alerting the user that the UPS will soon run out of battery power and will shut itself down.
Restore utility power to connected equipment by plugging the UPS power cord back into a wall outlet.
Backup all unsaved files before you perform the power outage simulation test. If monitoring software has been
installed in the computer, then verify if the software saves the file and shut down the UPS automatically
2.6 Visual and audible alarms
Visual indicator
Meaning
st
1
green LED lit
AC mode: UPS ON
st
1
green LED flashing
Back up mode: UPS ON
nd
th
2
to 5
Green LEDs lit
AC mode: load level
Back up mode: battery capacity
Red LED lit
Fault
3. Monitoring Software
Each UNITEK UPS is delivered with its monitoring software, however you can download COMMANDER PRO from the
UNITEK web site:
Go to the UNITEK web site : www.unitek-europe.com
Click on the Download / Software menu and follow the link to Commander Pro
Click Commander Pro Icon to enter software download area.
Select the operating system of your computer and double click to download the software automatically.
During software installation, type in the serial number below:
Commander Pro SERIAL Number
511C1-01220-0100-478DF2A
4. Service and Maintenance
4.1 Routine Maintenance
Use dry soft clothes to clean the front panel and plastic parts. Do not use any detergent containing alcoholic
ingredients.
The expected lifetime of the battery is around 3 years. Improper operation and harsh environment will reduce the
actual lifetime.
Unplug the UPS from power inlet if the UPS will not operate for long period of time.
Charge the battery every 3 months to recover the self discharge when the UPS is in extended storage.
When replacing batteries, use the sealed lead-acid maintenance free battery with the same voltage and capacity.
Proper disposal of batteries is required. Refer to your local codes for disposal requirements.
4.2 Storage instructions
The UPS should be stored in a cool dry location. Make sure the battery is fully charged when the UPS is stored.
For extended storage in moderate climates, the battery should be charged for 12 hours every 3 months by plugging the
power cord into the wall receptacle and turning on the main switch. Repeat every 2 months in high temperature
locations.
Audible Alarm
Meaning
1 beep every 10 seconds
Back up mode
1 beep every second
Battery low
2 beep every second
Overload
Continuous beep
Fault
17
4.2 Battery removal
Disconnect all sources of supply before battery replacement.
Remove the front panel
Remove the battery cover
Gently extract the battery by disconnecting the two wires connected to the UPS.
Be sure to replace with the same type of batteries and dispose of old batteries.
5. Troubleshooting
The TROUBLESHOOTING TABLE in the next paragraph covers most of the questions that you may emerge under
normal working conditions. If the UPS fails to operate properly, please review the following steps before calling the
repair center:
1. Is the UPS plugged into a properly working outlet?
2. Is the line voltage within the specified range?
3. Does the circuit breaker on the rear panel need to be reset?
Please do not open the metal cover. There are no user serviceable parts inside.
The batteries contained in this UPS are recyclable. The batteries contain lead and poses a hazard to the
environment and to human health if not disposed of properly.
Do not open or mutilate the batteries. They contain electrolytes which is toxic and harmful to the skin and eyes.
A battery can present a risk of electrical shock and high short circuit current. When replacing batteries, wrist
watches and jewelry such as rings should be removed. Use tools with insulated handles.
Please note the following information when you call or send an e-mail for service:
1. Model No. / Serial No.
2. Date of purchase
3. Full description of problem.
5.1 Trouble Shooting Table
Abnormal Situation
Cause
1. Low battery level
No LED display on
2. Battery defect
front panel
3. Power switch was not pressed and
held for at least 10 seconds
Alarm buzzer beeps
continuously when AC
UPS Overload
supply is normal
1. UPS Overload
During power failure,
2. Battery voltage is too low.
backup time is too
3. Battery defect due to high
short
temperature operation environment, or
improper operation on battery
Communication lost
1. Software is not properly installed
between UPS and
2. Cable is not properly connected
computer.
It is advised that the battery replacement should be conducted by an authorized technician and with a battery of the
same type and capacity.
Solution
1. Recharge battery up to 8 hours
2. Replace with the same type of battery
3. Press and hold switch for at least 10 seconds
Verify that the sum of the load matches the UPS
capacity specified in the specifications
1. Remove least critical load
2. Recharge battery 8 hours or more
3. Replace with the same type of battery
1. Re-install the software
2. Check that RS-232 cable is firmly connected to the
UPS and to computer COM1/COM2
18