7.2)Programming of activation codes (DIP2 OFF)
The Enter function is obtained by simultaneously
pressing key 0 and key 8. Programming can only be
carried out when the pushbutton panel is supplied
with power.
1 Press Enter (0+8) N times, where N represents the
number of figures wanted to make up the activation
code (from 3 to 6 figures).
2 Type the memory location used by the code (from
0 to 15) and press Enter (0+8). A maximum of 16
different codes are therefore possible.
3 Type the number of the serial zone be controlled
with the code (from 1 to 127) and press Enter (0+8).
Do not enter value 0.
4 Enter the activation code, having 3 to 6 figures (see
point 1), and press Enter (0+8).
5 If Enter (0+8) is pressed again within 10s, the
procedure is resumed from point 2 (entering
position⇒zone⇒code).
For example. to attribute code 88776 to position 12,
in order to activate serial zone address 2, proceed
as follows:
1 Press Enter (0+8) 5 times
2 Type 12 (location number) and press Enter (0+8)
3 Type 2 (zone number) and press Enter (0+8)
4 Type 88776 (access code) and press Enter (0+8)
5 To end programming, press any key or wait for 10s.
At the end of programming, reposition DIP2 to ON.
7.3) Making changes to a pushbutton panel already
programmed (DIP2 OFF)
Note: To be able to add codes and/or change pu-
shbutton panel programming, it is indispensable
to know at least one valid code number.
7.3.1) Addition of new codes
1 Press Enter (0+8) 3 times.
2 Type a valid code number entered in the memory
and press Enter (0+8).
3 Type the memory location taken up by the code
to be added (from 0 to 15) and press Enter (0+8).
Using a location already taken up causes the pre-
vious code to be cancelled.
4 Type the number of the serial zone to be controlled
with the code (from 1 to 127) and press Enter (0+8).
Do not enter value 0.
5 Enter the activation code, having 3 to 6 figures,
depending on the number of figures set in the
first programming phase (par. 7.2), and press Enter
(0+8).
6 If Enter is pressed again, the procedure is resumed
from point 3 (entering position⇒zone⇒code).
7 To end programming, press any key or wait for 10s.
7.3.2) Cancellation of codes
This operation is used to cancel all the previously
programmed codes and settings from the memory.
1 Press Enter (0+8) 4 times.
2 Type a valid code number.
3 Press Enter (0+8) and keep it pressed for at least
10s.
4 It is now possible to proceed to a new programming
procedure (see par. 7.2).
At the end of programming, reposition DIP2 to ON.
8) WARNING
1) Waiting over 10s between typing one figure and
the next causes the entry to be cancelled, and
therefore it must be repeated.
INSTALLATION MANUAL
2) The acoustic signal can emit 3 types of sounds:
brief single sound
long sound
brief continuous sound = error (function not
valid)
3) After consecutive entry of 5 invalid codes, the
acoustic signal emits the error sound for 60s,
during which time no other attempts at access
can be made. Any further incorrect code causes
other error signals to be emitted, with consequent
waiting time.
4) Record the code numbers entered, especially in the
case of installations having numerous access codes.
The table in Fig.H can be filled in and given to the
user. Keep these instructions and the access codes
in a safe place which is only known to authorised
persons.
9) MAINTENANCE
Installation maintenance must exclusively be
carried out by qualified personnel.
10) SCRAPPING
ATTENTION: disposal should only be carried out
by qualified personnel.
The descriptions and illustrations contained in the
present manual are not binding. The Company
reserves the right to make any alterations deemed
appropriate for the technical, manufacturing and
commercial improvement of the product, while
leaving its essential features unchanged, at any
time and without undertaking to update the pre-
sent publication.
THE DECLARATION OF CONFORMITY CAN BE
VIEWED ON THIS WEBSITE: WWW.BFT.IT IN THE
PRODUCT SECTION.
= number entered
= Enter (0+8) typed
Materials must be disposed of in accor-
dance with the regulations in force. Do not
throw away your discarded equipment or
used batteries with household waste. You
are responsible for taking all your waste
electrical and electronic equipment to a
suitable recycling centre.
11
Q.BO PAD -

Publicidad

Tabla de contenido
loading

Productos relacionados para BFT Q.BO PAD

Tabla de contenido