VII.
RUST PROTECTION MAGNESIUM ANODE
The magnesium anode protects the water tank's
inner surface from corrosion. The anode element is an
element undergoing wear and tear and is subject to
periodic replacement.
In view of the long-term and accident free use of your
water heater, the manufacturer recommends periodic
inspections of the magnesium anode's condition by
a qualified technician and replacement whenever
required, and this could be performed during the
appliance's technical preventive maintenance.
For replacements, please contact the authorized service
stations! This service is not provided under warranty
maintenance.
PERIODIC MAINTENANCE
VIII.
Under normal use of the heater, under the influence of
high temperature, lime scale /the so-called lime scale
layer/ is deposited upon the heating element's surface.
This worsens the heat exchange between the heating
element and water. The heating element's surface
temperature increases along /of boiling water/.
The thermoregulator begins to switch on and off
more frequently. A ''deceptive" activation of the
thermal protection is possible. Due to these facts, the
manufacturer recommends preventive maintenance
of your water heater every two years by an authorized
service center or service base. This protective
maintenance must include cleaning and inspection of
the anode protector (for water heaters with glass-
ceramic coating), which shall be replace with a new one
if need arises.
In order to clean the appliances use a damp cloth. Do
not clean with abrasive or solvent content detergents.
Do not pour water over the appliance.
The manufacturer does not bare the responsibility for all
consequences caused by not obeying the instructions,
given hereby.
Environmental protection instructions
Old electric appliances contain prescious materials
and must not be disposed with the domestic
waste! Please make your active contribution to the
protection of the environment and dispose of the
appliance in the stations organized for the purpose
(if available).
English
DESCRIPTION TO ANNEX I
(1) supplier's name or trade mark (2) supplier's
model identifier (3) the declared load profile, expressed
by the appropriate letter and typical usage in
accordance with Table 3 of Annex VII (4) the water
heating energy efficiency class of the model, determined
in accordance with point 1 of Annex II (5) the water
heating energy efficiency in %, rounded to the nearest
integer (6) the annual electricity consumption in kWh in
terms of final energy and/or the annual fuel
consumption in GJ in terms of GCV, rounded to the
nearest integer and calculated in accordance with point
4 of Annex VIII (7) the thermostat temperature settings of
the water heater, as placed on the market (8) the daily
electricity consumption Q elec in kWh, rounded to three
decimal places (9) the declared load profile, expressed by
the appropriate letter in accordance with Table 1 of this
Annex (10) the mixed water at 40 °C V40 in litres,
rounded to the nearest integer;(11) maximum
temperature of the thermostat (12) 'out of the box-mode'
is the standard operating condition, setting or mode set
by the manufacturer at factory level, to be active
immediately after the appliance installation, suitable for
normal use by the end-user according to the water
tapping pattern for which the product has been
designed and placed on the market (13) the water
heating energy efficiency in %, rounded to one decimal
place (14) All specific precautions for assembly,
installation and maintenance are described in the
operating and installation instructions. Read and follow
the operating and installation instructions. (15) All of the
data that is included in the product information was
determined by applying the specifications of the relevant
European directives. Differences to product information
listed elsewhere may result in different test conditions.
Only the data that is contained in this product
information is applicable and valid.
Instructions for use and maintenance
EN
11