9. TROUBLESHOOTING
PROBLEM
When you switch the machine on with the main switch on the console, nothing happens.
CAUSES
1) The plung has not been connected to the power socket.
2) No electricity delivered from the mains.
REMEDIES
1) Insert the plug into the power supply socket.
2) Do whatever is required to re-establish mains supply.
PROBLEM
2
When you switch the machine on with the main switch on the console, the
carriage movement hydraulic controls do not work.
CAUSES
1) The overload cut-out for the hydraulic pump motor has tripped.
2) The hydraulic pump motor turns in the opposite direction to that shown by the arrow (3).
3) Insufficient hydraulic fluid in the hydraulic plant reservoir.
1
REMEDIES
1) Reset the overload cut-out by pressing the green button (1).
2) Have an electrician switch two wires in the plug.
3) Top it up to level following the instructions given in the section on "MAINTENANCE"
of this manual.
3
PROBLEM
When you switch the machine on with the main switch on the console,
spindle rotation does not work.
CAUSES
1) Spindle motor overload cut-out has tripped.
REMEDIES
1) Reset the overload cut-out by pressing the green button (2).
52