Output Specifications

General
Description
Relay and FET Outputs
Maximum Controlled Load
Maximum Continuous Current:
Current per Group Common
Current per Controller
Relay Outputs
Turn On Time/Turn Off Time
Load Current
(1)
scan time dependent
Relay Contact Ratings
Maximum Volts
240V ac
120V ac
125V dc
24V dc
(1)
For dc voltage applications, the make/break ampere rating for relay contacts can be determined by dividing 28 VA by the
applied dc voltage. For example, 28 VA/48V dc = 0.58A. For dc voltage applications less than 14V, the make/break ratings
for relay contacts cannot exceed 2A.
(2)
1.5A above 40°C.
1762
-L24AWA
-L24BWA
-L24AWAR
-L24BWAR
1440 VA
8A
at 150V max
30A or total of per-point loads, whichever is less
at 240V max
20A or total of per-point loads, whichever is less
10 msec (minimum)
10 mA (minimum)
Amperes
Make
Break
7.5A
0.75A
15A
1.5A
(1)
0.22A
(1)
1.2A
MicroLogix™ 1200 Programmable Controllers
-L24BXB
-L24BXBR
7.5A
(1)
Amperes
Continuous
(2)
2.5A
(2)
2.5A
1.0A
2.0A
Publication 1762-IN006D-MU-P - March 2004
-L40AWA
-L40BXB
-L40BWA
-L40BXBR
-L40AWAR
-L40BWAR
8A
8A
Volt-Amperes
Make
Break
1800 VA
180 VA
1800 VA
180 VA
28 VA