RIDGID RD907000P Manual Del Operador página 24

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

MAINTENANCE
REPLACING FUEL FILTER
See Figure 24.
Occasionally the fuel filter may become clogged and need
to be replaced. To purchase a replacement fuel filter contact
customer service or a qualified service center
To replace:
 Turn the fuel valve to the OFF ( O ) position.
 Remove the fuel lines from both sides of the filter by
squeezing the ends of the retaining clips with pliers.
 Slide the fuel lines off.
 Replace with new fuel filter.
 Reinstall fuel lines and retaining clips to new fuel filter.
 Turn the fuel valve to the ON ( I ) position.
CHANGING ENGINE BATTERY CHARGE
CIRCUIT FUSE
See Figure 25.
NOTICE:
Do not use a higher rated fuse other than the
specified amperage. This could cause damage to
the product.
 Grip both sides of the plastic fuse holder and twist apart
to reveal the fuse.
NOTE: A replacement fuse is installed inside the fuse
holder.
 Insert the new fuse and refasten the fuse holder by push-
ing the two sides of the connector together and twisting
to secure.
TRANSPORTING
 Turn the engine switch OFF (O). Disconnect any equip-
ment that is plugged into the generator.
 Verify the fuel valve is in the OFF position.
 Allow 30 minutes of "cool down" time before transporting
the machine. Make sure engine and exhaust of unit are
cool.
 Lower the handle.
 Keep unit level while transporting to prevent fuel spillage.
 Do not drop or strike unit or place under heavy objects.
 If transporting in a vehicle, drain the fuel tank, close the
fuel valve, and securely restrain the generator.
 Provide a plastic sheet or absorbent pad below the gen-
erator to catch any drips of fuel or lubricant.
This product has a Three-year Limited Warranty. For warranty
details, visit www.rigid.com or call (toll free) 1-866-539-1710.
USING THE BATTERY MAINTAINER
See Figure 26.
When storing the generator, the battery maintainer can be
connected to keep the battery fully charged and ready for
use.
NOTE: The battery maintainer provided should only be
used with the 12V 9AH/HR12-36W lead acid battery model
RT12-90H supplied with this generator.
 Connect the battery maintainer to the power supply. Make
sure the power supply is normal household voltage, 120
volts, AC only, 60 Hz.
 Attach the other end of the battery maintainer to the
charging cable attached to the battery. The red light on
the plug will illuminate to show the battery is charging.
The battery will become slightly warm to the touch while
charging. This is normal and does not indicate a problem.
When battery is fully charged, the red light will turn green.
NOTE: If the light does not illuminate, the fuse on the
charging cable may need to be replaced. Check the fuse
and replace if needed.
 Disconnect the battery maintainer before operating the
generator. Place the cover on the charging cable when
not in use.
BATTERY REMOVAL AND PREPARATION FOR
RECYCLING
To preserve natural resources, please recycle
or dispose of batteries properly.
This product uses lead acid batteries. Local,
state or federal laws may prohibit disposal of
batteries in ordinary trash.
Consult your local waste authority for information regarding
available recycling and/or disposal options.
WARNING:
Upon removal, cover the battery's terminals with
heavy-duty adhesive tape. Do not attempt to
destroy or disassemble battery or remove any of its
components. Lead acid batteries must be recycled
or disposed of properly. Also, never touch both
terminals with metal objects and/or body parts as
short circuit may result. Keep away from children.
Failure to comply with these warnings could result
in fire and/or serious injury.
18 — English

Publicidad

Tabla de contenido
loading

Tabla de contenido