Mounting instructions for water installers:
Important: Read these instructions thoroughly before
installing the appliance. Determine the precise position in
the salon with the salon owner and the installation
specialist.
The wash unit is intended for operation in clean and
•
dry rooms at normal room temperature.
In the water supply system only original components
•
supplied by the manufacturer must be used.
The wash unit must only be connected to a water
•
supply where the supply pressure does not exceed
20 bar (20 MP a).
The new set of hoses supplied with the unit must be
•
used. Old hoses must not be used.
1.
The water supply pipes to the wash unit must be
equipped with an "Aqua-Stop" system.
2.
Place the mounting template at the determined
position and use it to drill the required holes.
Observe the notes on the mounting template!
3.
Make the holes for cold water (K), hot water (W)
and waste water (A).
4.
Lead ½" pipes for the hot and cold water supply
and 40 mm dia. drain pipe with connecting sleeve for
the siphon through the floor.
5.
Ensure that the stop valves and siphon are at the
correct position and correctly spaced (see the
mounting template).
6.
Height of the connecting pipes and drain pipe:
½" pipe: 50 mm above finished floor 40 mm dia. drain
pipe: 50 mm above finished floor
Mountinge instructions for appliance fitters:
7.
Take away the backside cover (1) from the base:
Hold the cover at the front edge on both sides,
pull apart and remove to the rear.
Remove front cover (2) from the base (3) as shown in
fig. 1
8.
only with in-line installation for water pipes:
Prepare the backside cover (1) for connection of the
installation tunnel:
- cut out a 145 x 115 mm section as shown in fig. 2
- Make sure that the mounting side corresponds to
that shown in the installation diagram!
9.
Align the base (3) according to the installation
template and secure to the floor.
4 anchor bolts M 10 x 125 (extending 30 mm above
the finished floor) or metal plugs with metric thread
for hexagonal screws M 10 x 60.
Diner Shiatsu MO B+R
GB
Mounting instructions for water installers:
10. Make sure that pipes/pressure hoses and drain hose
are parallel. Connect the unit. Prevent the stop
valves from turning while they are being
screwed on. Connect the waste water hose to the
siphon using a seal and union nut. Insert the waste
water hose at least 3 to 4 cm into the siphon. Connect
the drain bushing to the waste water hose using a hose
clamp.
11. Close the mixing tap. Open the stop valve and check
for leaks with the mixing tap closed. Check the mixed
water. The hot water and cold water supply must
correspond to the coloured symbols
on the mixing tap.
12. Check the pressure of the unit with 8 bar water
pressure. Then set the pressure to 3 to 5 bar. On
completion of the installation work, always rinse out the
water pipes. A central regulating tap is required if more
than one unit is installed. This tap must be easily
accessible from the salon.
These mounting instructions apply to the connection
of one unit. If more than one unit is to be installed, the pipe
cross section must be increased
accordingly.
Important: If the water pressure is above 5 bar, it must be
regulated by a pressure reduction valve. Since a pressure
reduction valve is used for boilers, such a valve can be fitted
along the common water
supply line.
Note for salon owners:
The connections described under points 1 to 6 and 10 to 12
must be performed by the installer. The installer is responsible
for any problems that may occur. The manufacturer of the unit
shall not accept warranty claims for this work.
Mounting instructions for electricians:
13. Electrical connection:
Caution:
With direct wiring cut connection cable and connect it
•
with as little excess length to the floor cable.
The wash unit with power supply cable must not be
•
connected to the power supply using an extension
cable.
Arrange the power supply cable so that the plug is
•
easily accessible and can be isolated from the wall
socket.
In case several wash units are to be installed in-line,
•
the power supply cable must not be connected via
further units.