Aprimatic Flexi 300EL Manual De Instrucciones página 28

Central de comando para 2 motores 24vdc
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

12 - OTHER CONNECTABLE ACCESSORIES
12A - FLASHING LAMP
It is possible to connect flashing light devices to the "LAMP" input (terminals 8,9). These devices turn on a second before the
manoeuvre. If the dip 5 "LAMP" is ON position, the power supplied is intermittent. Therefore, a normal lamp can be connected. If
the dip 5 "LAMP" is OFF position, the power supplied is direct. Therefore the terminals must be connected to a flashing light with
a built-in oscillating circuit.
The lamp must be 24 Vdc, and power rating must not be greater than 15W.
!
12B - ANTENNA
It is possible to connect a radio frequency antenna to the "ANT" input (terminals 1,2). The control unit is provided with a pre-
connected cable. In particular environmental conditions, it can be useful to connect an external antenna, to increase the
transmitter range.
In case of connection of external antennas, it is necessary to remove the pre-connected cable.
!
12C - OPENED GATE WARNING LIGHT
If the safety device self-test is not used (see paragraph 11C), the output "+TX" (terminal 20) acts as a gate open warning light.
The status of the lamp is as follows:
- If the access is closed the light is switched off
- If the access is open is alight with a fixed light
- If the access is opening the lamp flashes.
- If the access is closing the lamp flashes quickly.
The warning light must be 12 Vdc and it can't be more than 3W.
!
12D - ELECTRO LOCK (OPTIONAL CARD)
It is possible to manage an electro lock (maximum power 15W) using an accessory card (ELC Flexi). If the electro lock is 12Vdc,
it is possible to get the power supply directly from the control unit (more info on "Selc12" manual); if the electro lock is 24Vdc, it
necessary to get the power supply externally.
If the electro lock is connected, it could be necessary to set the dip 6 "Strike" to ON position, to have a stroke
!
reversing pulse at the beginning of the opening, and at the end of the closing.
12E - BUFFER BATTERIES (OPTIONAL CARD)
It is possible to connect two 12Vdc batteries in series (or one 24Vdc battery), max 7Ah, using a battery charge card
(SCB Flexi).
The quantity of cycles achievable with batteries depends on the power of the motors, and on the Ah of the batteries.
!
12F - COURTESY LIGHT (OPTIONAL CARD)
Thanks to an optional card (ELC Flexi), it is possible to manage a courtesy light (230Vac, max 500W). The output contact is
free, and it is provided before every manoeuvre for a customizable time from 0 to 120 seconds.
13A - "MEMO" MODULE
"MEMO" module is a memory card (see paragraph 1A) which stores the radio transmitters codes (see paragraph 3A and/or 3B).
13B - "RX" MODULE
The RX module is necessary to receive the radio transmitters frequencies (433.920 MHz).
It doesn't contain the radio codes.