Water filter
Clean the water filter regularly or when the water flow becomes smaller than usual.
NOTICE
Product / property damage due to wrong cleaning / assembly
Wrong cleaning and assembly of water filter can lead to product or water damage.
> Do NOT use detergent.
> Do NOT use excessive force.
> DO NOT use screw drivers to dismantle and assemble the water filter.
> Make sure the O-rings are in place before attaching water filter. Do NOT distort
the O-rings.
1
1
2
> Remove side
panel.
Descaling
NOTICE
Product damage due to limescale build-up
In regions with hard water, limescale build-up can impair the performance of the
product.
> Descale the product regularly (
> Only use descaling agents provided or approved by Duravit.
Water hardness
soft
<8.4° dH (1.5 mmol/l)
moderate
8.4 – 14° dH (1.5 – 2.5 mmol/l)
hard
>14° dH (2.5 mmol/l)
Table 5: Descaling cycles
The descaling process can be activated via app
> Follow the instructions provided in the app.
2
> Follow instruc-
tions next to the
filter.
Table 5: Descaling cycles.)
3
2
1
> Attach side
panel.
Descaling cycle
every six months
every six months
quarterly
EN