tau K892M Guía Para La Instalación página 6

Ocultar thumbs Ver también para K892M:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

SENSITIVE EDGE/
14 - 15
PHOTOCELLS
16 - 17
STOP
16 - 18
OPEN/CLOSE
19 - 20 - 21 MOTOR 1
22 - 23 - 24 MOTOR 2
STOP
OPEN/CLOSE
M5
FCC
FCA
Note: if the card is fitted in replacement of an older model (K595M, K696M, K797M or K898M)
there is no M5 terminal block. In its place is a terminal block with 3 screw units that must be
wired as follows:
25 - 27
FCA
26 - 27
FCC
M9
ENCODER
6. NEW K892M FUNCTIONS (software version 3.10)
Board power-up:
On power-up with DIP4 set to ON, the board checks whether the work time is memorised. If this is not de-
tected, led DL7 flashes quickly, to indicate that the stroke setup procedure needs to be performed.
In all other cases, the first manoeuvre performed by the board is opening, unless already positioned
against one of the limit switches. During this phase, the board does not accept O/C inversion (Open/Close).
Input for pressure-sensitive edge (mechanical edge) or other safety de-
vices, e.g. photocells (NC contact);
14 = pressure-sensitive edge; 15 = Common;
Stop push button NC (normally closed) contact. After a stoppage, the system
always starts again with an opening phase and only after receiving a com-
mand from the On button or radio transmitter. 16 = Common; 17 = Stop;
Input for open/close push button (normally-open contact): for usage, see
the functions of dip switches 2-3;
Motor (1) output; 19 = Closing phase; 20 = Common; 21 = Opening phase;
Auxiliary motor (2) output;
22 = Closing phase; 23 = Common; 24 = Opening phase;
PIN1
Input for STOP push button
PIN2
Input for OPEN/CLOSE push button
PIN3
Common GND
PIN4
Input for closing limit switch FCC
PIN5
Input for opening limit switch FCA
Open limit switch input (Normally Closed contact) FCA; 27= Common;
Close limit switch input (Normally Closed contact) FCC; 27= Common.
Encoder quick connector
PIN COM BLUE negative
PIN +5V BROWN positive
PIN ENC WHITE signal
16 = Common; 18 = Open/close;
6