4
DECELERATION
PRE-
5
FLASHING
6
SETUP
2
RADIO CH
nd
7
with software version 3.10 onwards:
n°6 Off and n°7 Off:
Gate open contact: the contact activates on gate opening, remains active during the opening time, dur-
ing the TCA and during closure again. It is deactivated once the gate has completed closure.
8
ENCODER
PRESSURE-SENSITIVE
9
EDGE
INTERNAL
10
PUSH-BUTTON
IMPORTANT:
Each pair of terminals attached to an NC contact that is not in use must be short-circuited in order to
ensure the proper operation of the board.
The input related to the pressure-sensitive edge must not be short circuited. The device is turned off by set-
ting dip 9 to OFF.
The door's earthing system must comply with current standards. The manufacturer will accept no li-
ability for any damage deriving from failure to comply with this requirement.
SOFTWARE Version 1.05 ÷ 3.00 - Table 1
Software version 1.05 includes the option to set the duration of deceleration and sensitivity of the
"obstacle detection" function, made possible by means of an encoder (optional). These functions can
be enabled by means of dipswitches 4 and 8 and are settable by means of the trimmers on the board,
as shown in table 1.
DIP 4 DIP 8
No deceleration
OFF
OFF
No ENCODER
Optional LS (limit switches)
with software version 1.04 and previous versions
On
the deceleration function is on (for motors with limit switch only).
Off
the deceleration function is off.
with software version 1.05 ÷ 3.00, see table 1.
with software version 3.10 onwards, see table 2.
preflashing enabled, each time the gate is operated the light starts flash-
On
ing 3 seconds before the gate begins to move.
Off
when the gate is started, it will move immediately.
monostable function of the CH2 control relay (terminals 9 and 10) ena-
On
bled.
bistable (or STEP-BY-STEP) function of the CH2 control relay (terminals 9
Off
and 10) enabled.
with dip-switch 6 ON (monostable function), the N.O. contact remains
On
closed for 180 secs. (fixed invariable delay for the timed control of the
lights).
with dip-switch 6 ON (monostable function), the N.O. contact remains
Off
closed for 2 secs. (fixed invariable delay for commanding a second auto-
matic system).
with software version 1.04 and previous versions
not used.
with software version 1.05 ÷ 3.00:
On
encoder enabled (see table 1)
Off
encoder disabled.
with software version 3.10 onwards:
On
encoder enabled (see table 2)
Off
encoder disabled.
On
pressure-sensitive edge on.
Off
pressure-sensitive edge off.
internal push-button panel off. The OPEN/CLOSE and STOP buttons on
On
the lid of the automation are off. Therefore it is not necessary to short
circuit the terminals.
internal push-button panel on. The OPEN/CLOSE and STOP buttons on
Off
the lid of the automation are on.
Set mode
TM1
Automatic
closure
Work time
time
8
TM2
TM3
Not used