tau S-500K123M Guía Para La Instalación página 15

Panel de mandos para motorreductor master12q
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

GATE OPEN
9 - 10
WARNING LIGHT
SENSITIVE
11 - 13
12 - 13
PHOTOCELLS
14 - 15
14 - 16
OPEN/CLOSE
14 - 17
PEDESTRIAN
18 - 19
2
RADIO CH
nd
20 - 21
AERIAL
22 - 23 - 24
ENCODER
25 - 26
BATTERY
POWER
FS1 - FS2
SUPPLY
MEMORIZATION PROCEDURE
WARNING: After powering the control panel, wait 2 seconds before you start performing the
adjustment operations.
Note: The gate must be equipped with the opening and closing safety stops.
When you have completed the installation procedures :
1_ bring the gate to approx. 1 m from the closing travel limit;
2_ set dip-switch no. 8 to ON;
18V DC max. 3W output for supply to open and moving gate
warning light (9 = NEGATIVE - 10 = POSITIVE);
N.C. input for electromechanical sensitive edge – it cuts in during
the opening manoeuvre, locking and re-closing the gate by ~20
EDGE
cm (11 = C.F. - 13 = COM);
N.C. photocell input - it cuts in during the closing or the opening
manoeuvre, see dip-switch no. 3 (12 = FOT - 13 = COM);
Note: the photocell transmitter must always be supplied by
terminals no. 5 and no. 6, since the safety system test (pho-
totest) is carried out on it. Without this connection, the con-
trol unit does not work. To override the testing of the safety
system, or when the photocells are not used, set dip-switch
no. 6 to OFF.
N.C. input for STOP button – It stops the gate in any position,
temporarily inhibiting its automatic closing, if programmed (14
= COM - 15 = STOP);
NOTE: A safety micro-switch is connected to the STOP push-
button. In case the STOP input remains open for more than 5
STOP
seconds, the operator will perform a cycle at a slow speed to
reset the operating parameters to the values originally saved
(see "Restoring automatic operation"). The micro-switch
should be connected in series to further STOP push-buttons
where present.
N.O. input for OPEN/CLOSE button - It commands the opening
and closing of the gate and its operation is controlled by dip-
switches 2 and 3 (14 = COM - 16 = A/C);
N.O. input for PEDESTRIAN button - It commands the partial
opening and closing of the gate for ~1 m of travel and its opera-
tion is controlled by dip-switches 2 and 3
(14 = COM - 17 = PED);
2
radio channel output - for control of an additional automation
nd
or for switching on lights, etc... (N.O. clean contact);
Warning: to connect other devices to the 2nd Radio Channel
(area lighting, pumps, etc.), use an additional auxiliary relay
(with receiver connected).
plug-in radio-receiver aerial input , for 40.665 MHz receivers only
(20 = SIGNAL - 21 = GROUND);
encoder supply and input (22 = BLUE negative - 23 = BROWN
positive - 24 = WHITE signal);
battery 12V - 7,2Ah input;
board supply input 13.5 Vac – Powered by the toroidal trans-
former housed in the MASTER12Q motor and protected by a
fuse on the 230 Vac power supply ;
K123M
15