tau S-500K123M Guía Para La Instalación página 16

Panel de mandos para motorreductor master12q
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

3_ operate the automation using one of the following inputs: A/C, radio control or card button.
4_ the gate must start to close.
Note: if it opens, stop the programming procedure by resetting the electric panel (disconnect
the power supply to the panel for at least 5 sec. and set dip-switch no. 8 to OFF); with the con-
trol panel disconnected, exchange the motor supply wires. Restart the procedure from point 1.
5_ when the gate has closed, after approximately 2 seconds a complete opening manoeuvre is ex-
ecuted automatically;
6_ when the gate has opened, set dip-switch no. 8 to OFF;
7_ the automation is now ready for operation.
Make the logic adjustments.
Nota: when any adjusting devices (trimmers or dip-switches) on the control panel are operated,
a complete manoeuvre must be carried out in order for the new settings to take effect.
LOGIC ADJUSTMENTS
TRIMMER
RALL.
slowdown distance adjustment: from about 10 to 100 cm;
T.C.A.
Automatic Closing time adjustment: from about 3 to 255 seconds (see dip-switch
no. 1);
FR.
obstacle detection sensitivity adjustment.
NOTE:
by rotating the TRIMMER FR. clockwise the sensitivity of the gearmotor to
obstacles diminishes and therefore the thrust force increases; vice-versa, by
rotating it counter-clockwise, the sensitivity of the gearmotor to obstacles
increases and therefore the thrust force diminishes.
Dip switch
Do not use metal tools (such as a screwdriver) to set the dipswitches to prevent risks
of short circuit with the radio receiver terminals.
AUTOMATIC
1
CLOSING
2
2 / 4 STROKE
OPENING
3
PHOTOCELLS
OPERATION
4
NO REVERSE
PRE-
5
FLASHING
PHOTOCELL
6
TEST
CLOSE
7
AFTER
PHOTOCELL
16
when the gate has opened, it closes automatically after the time estab-
On
lished through the T.C.A. trimmer;
Off
the closing manoeuvre requires a manual command;
when the automation is operational, a sequence of opening/closing com-
On
mands causes the gate to OPEN-CLOSE-OPEN-CLOSE etc.
under the same circumstances, the same sequence of commands causes
Off
the gate to OPEN-STOP-CLOSE-STOP-OPEN-STOP, etc. (step-by-step
function) (see also dip switch 4);
during the opening phase, the photocell cuts in, stopping the gate until the
On
detected obstacle has been removed. During the closing phase, it causes
the gate to stop and then to open again all the way;
during the opening phase the photocell does not cut in, while during the
Off
closing phase it behaves in the same way as it does when in the ON mode;
On
the gate behaves as established by dip switch no. 2
Off
the gate ignores the closing commands during the opening manoeuvre;
On
the pre-flashing function is enabled;
Off
the pre-flashing function is disabled;
On
the "photocell test" function is enabled;
the "photocell test" function is disabled.
Off
Note: to be used when the photocells are not used;
following the connection of the photocell contact (input 12 - 13), the gate
On
closes automatically after 5 seconds;
Off
function disconnected;
K123M

Publicidad

Tabla de contenido
loading

Tabla de contenido