DITEC Dod123 Manual De Instalacion Y Manutencion página 8

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 16
1.
TECHNICAL DATA
GB
Power supply
Absorption
Motor torque
Revolution transmission shaft
Intermittence
Degree of protection
Temperature
Electrical board
2.
REFERENCE TO ILLUSTRATIONS
The given operating and performance features can only be
guaranteed with the use of DITEC accessories and safety
devices.
2.1 Geared motor references (fi g. 1-2)
[1]
Geared motor
[2]
Limit switch group
[3]
Carter
[4]
Support brackets
[5]
Base plate
[6]
Cord release device
[7]
Transmission shaft
[8]
Pinion
[9]
Adjusting bracket
3.
INSTALLATION EXAMPLES
Figure 6a: Sliding door (with transmission - lateral fi xing)
Figure 6b: Bi-folding (with transmission - lateral fi xing)
Figure 6c: Sliding door
Figure 6d: Vasistas
4.
ACCESSORIES
Cat1
Chain 1/2" (5 m)
CatG
Joint for 1/2" chain
DodP15
1/2" pinion for chain
DodMA
Coupling for 1" pipe
DodTC
Chain pull kit
Deb04/08
Key release
DodRIN1
Chain transmission kit
5.
INSTALLATION
Unless otherwise specifi ed, all measurements are expressed
in millimetres (mm).
-
Assemble the selected pinion (DodP15) onto transmission
shaft [7].
-
Based on the type of installation (see "INSTALLATION
EXAMPLES" pag. 3) install the gearmotor and the relative
assembly accessories (shows in table on pag. 3).
-
(Fig.4) Tighten the chain by means of the bracket [9].
-
(Fig. 4) Assemble the cord-fi tted release device [6] (provided)
or the Deb04 key-release device (see Deb04 instructions) to
release/lock the geared motor.
-
Limit switch adjustment. (fi g. 3). With the door fully open,
adjust the related opening limit switch by turning the screw
so that the cam activates the opening microswitch.
With the door fully closed, adjust the related closure limit
switch by turning the screw so that the cam activates the
closing microswitch.
Note: Adjust the limit switches about 20 mm before the door
reaches the door stop.
DOD 123 - IP1844
Dod123
230 V~ / 50 Hz
3 A
24 Nm
56 RPM
S2 = 30 min. / S3 = 50%
IP20
-20° C / +55° C
E1F
6.
ELECTRICAL CONNECTION
Execute the electrical connections as indicated in fi g. 5.
[A] and [C] refer to the rotary limit switch adjustment
The electrical connections and starting are illustrated in the E1F
electronic panel installation manual.
7.
MAINTENANCE PROGRAM (each 6 months)
Power off and geared motor released (see OPERATING IN-
STRUCTIONS):
- Check for the stability of the automatism and check that all
the screws are tightened all the way.
- Clean the wheel sliding tracks, lightly lubricate the pinion, the
rack or the chain. Manually move gate to check that it slides
freely and smoothly.
Power on and geared motor lock (see OPERATING INSTRUC-
TIONS):
- Check the functioning of the limit switches (the door must
come to a halt about 20 mm before the stops).
- Check the power adjustments.
- Check the operation of all controls and safety functions.
Attention: For spare parts, see the spares price list.
All right reserved
All data and specifi cations have been drawn up and checked
with the greatest care. The manufacturer cannot however take
any responsibility for eventual errors, ommisions or incomplete
data due to technical or illustrative purposes.