Descargar Imprimir esta página

Blackmagic Design URSA Mini Manual De Instalación Y Funcionamiento página 2307

Ocultar thumbs Ver también para URSA Mini:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 1166
Defined Commands
Command 0 : change configuration
Category (uint8)
Parameter (uint8)
Data type (uint8)
Currently defined values are:
0: void / boolean
1: signed byte
2: signed 16 bit integer
3: signed 32 bit integer
4: signed 64 bit integer
5: UTF-8 string
Data types 6 through 127 are reserved.
128: signed 5.11 fixed point
Data types 129 through 255 are available for device specific purposes.
Operation type (uint8)
0: assign value
1: offset / toggle value
Operation types 2 through 127 are reserved.
Operation types 128 through 255 are available for device specific purposes.
Data (void)
The category, parameter, data type and operation type partition a 24 bit operation space.
The category number specifies one of up to 256 configuration categories
available on the device.
The parameter number specifies one of 256 potential configuration
parameters available on the device. Parameters 0 through 127 are device
specific parameters. Parameters 128 though 255 are reserved for parameters
that apply to multiple types of devices.
The data type specifies the type of the remaining data. The packet length is
used to determine the number of elements in the message. Each message
must contain an integral number of data elements.
A void value is represented as a boolean array of length zero.
The data field is a 8 bit value with 0 meaning false and all other values
meaning true.
Data elements are signed bytes
Data elements are signed 16 bit values
Data elements are signed 32 bit values
Data elements are signed 64 bit values
Data elements represent a UTF-8 string with no terminating character.
Data elements are signed 16 bit integers representing a real number with
5 bits for the integer component and 11 bits for the fractional component.
The fixed point representation is equal to the real value multiplied by 2^11.
The representable range is from -16.0 to 15.9995 (15 + 2047/2048).
The operation type specifies what action to perform on the specified
parameter. Currently defined values are:
The supplied values are assigned to the specified parameter. Each element
will be clamped according to its valid range. A void parameter may only be
'assigned' an empty list of boolean type. This operation will trigger the action
associated with that parameter. A boolean value may be assigned the value
zero for false, and any other value for true.
Each value specifies signed offsets of the same type to be added to the
current parameter values. The resulting parameter value will be clamped
according to their valid range. It is not valid to apply an offset to a void value.
Applying any offset other than zero to a boolean value will invert that value.
The data field is 0 or more bytes as determined by the data type and number
of elements.
Информация для разработчиков
2307

Publicidad

loading

Este manual también es adecuado para:

Ursa mini pro