Maintenance and cleaning
•
If there is lint accumulation in the funnel
of the water tank, clean it under running
water.
•
Place the water tank into its seat.
C
If the direct water draining is
used as an option, there is no
need to empty the water tank.
6.4 Cleaning the condenser;
Hot and humid air in the condenser is cooled
with the cold air from the room. Thus, the hu-
mid air circulating in your dryer is condensed
and then pumped into the tank.
C
Clean the condenser after every
30 drying cycles or once a month.
To clean the condenser:
1. If a drying process has been carried out,
open the door of the machine and wait until
it cools down.
2. Unlock the 2 condenser locks after open-
ing the kick plate.
26 / EN
3. Pull out the condenser.
4. Clean the condenser by applying pressur-
ized water with a shower armature and wait
until the water drains.
5. Place the condenser in its housing. Fasten
the 2 locks and make sure that they are
seated securely.
6. Close the kick plate cover.
Dryer / User Manual