4. CONTROLS
To activate the Keyboard and its functions, press Button A. The keyboard will be displayed at half intensity. If it is not
used for 15 Seconds it will revert to its original status.
Button Function
A
Turns the Motor off.
Enables / Disables Keyboard Lock mode if pressed and
held for 2 seconds.
B
Activates speed one.
Pressing and holding the button for 2 seconds enables
the remote control.
Pressing and holding the button for 2 seconds disables
the remote control.
C
Activates speed two.
D
Activates speed three.
E
Activates Intensive speed. This speed is timed to run
for 6 minutes. At the end of this time the system will
automatically return to the speed set before.
It is disabled by pressing the Button or turning the
Motor off.
F
Activates Delay mode, with automatic shutdown of the
Motor, the Fans and the Lighting with a 15' delay.
It is disabled by pressing the button or turning the
motor off.
Press and hold the button for approximately 2 seconds,
with all the loads turned off (Motor and Lights), to turn
the Activated Charcoal Filter alarm on.
To turn it off, press and hold the button again for 2
seconds.
G
Press briefly to turn the lighting system on and off at
maximum intensity.
Holding the button down for 2 seconds to switch on the
lights at a intermediate brightness.
H
Press briefly, with all loads turned off (Motor+Lights),
when the filter alarm is active to reset the alarm. All the
Leds flash 3 times.
5. REMOTE CONTROL
(OPTIONAL)
10
Led
-
All the Leds light up in cycle.
The Button is fully lit.
All Leds flash twice.
All Leds flash once.
The Button is fully lit.
The Button is fully lit.
The button flashes once per second.
The Delay Led lights up.
All Leds flash twice.
All Leds flash once.
-
-
When the procedure terminates, the indication
shown previously turns off:
C+H Flashing
Indicates the need to wash the metal grease filters.
The alarm is triggered after the Hood has been in
operation for 100 working hours.
D+H Flashing
Indicates the need to change the activated charcoal
filters, and also to wash the metal grease filters.
The alarm is triggered after the Hood has been in
operation for 200 working hours.
6. LIGHTING
• For replacement contact technical support
("To purchase contact technical support").