Technical Personnel Menu; Only Authorized Personnel - Quality Espresso GAGGIA G6+ Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

7.2 TECHNICAL PERSONNEL MENU

7.2.1 – ONLY AUTHORIZED PERSONNEL
-
This menu is only for technical service personnel. It enables access by means of a password to a series of
menus in which we may configure and monitor the machine's parameters, aside from other types of functions.
Press to access the
next screen.
7.2.2 – MONITORAGE
Consult function which includes two sub-menus:
-
The first one is to check that the push button panels, work level probe and maximum level safety probe are
operating correctly.
-
The second one shows us the instantaneous temperature of each group (only for Grouptronic models).
If communication between the button
panel and control unit is correct, upon
pressing a button, the icon will
increase its intensity and will show the
service which is being performed.
Flowmeter impulses are displayed when any of programmed
buttons are pressed.
Press to select and write
the password.
Indicates that
the safety level
Indicates that the work
for the water in
level for the water in
the boiler is not
the boiler is in contact
in contact with
with the water.
the water.
39
The default entry password
i
is "1234". The technical
personnel should change
the password upon
installation.
Press to confirm and enter
into the "Only authorized
personnel" menu.
NEXT SCREEN
Indicates the temperature which the
thermocouple is reading in each of the groups
(only for Grouptronic model machines).
NEXT SCREEN