TROUBLE SHOOTING

PROBLEM
Machine does not operate.
Vacuum motor does not operate.
Brush does not operate.
Low suction
Poor brush pick–up.

SPECIFICATIONS

MODEL
LENGTH
WIDTH
HEIGHT
WEIGHT
BRUSH MOTOR
VACUUM MOTOR
POWER CORD LENGTH
SWEEPING PATH
VACUUM BAG
DECIBEL RATING AT
OPERATOR'S EAR, INDOORS ON
CARPET
6
CAUSE
ON/OFF switch is OFF.
Vacuum not plugged to wall outlet. Plug power cord to wall outlet.
Faulty power cord.
Faulty ON/OFF Switch.
Faulty wiring.
Building circuit breaker tripped.
Sensor temperature too high.
Brush circuit breaker tripped.
Vacuum bag full.
Vacuum hose plugged.
Secondary filter plugged.
Rear door gasket leakage.
Brush height adjusted incorrectly.
Clogged brush.
Worn brush bristles.
Loose drive belt.
3240
48cm
56cm
112cm
19.5Kg
230V, 0.15 kW/0.2 hp,.5 A, 1.800 rpm
230V, 1.12 kW/1.5 hp, 3.9 A
15m. Gauge–18/3
51 cm
10 L
70dB(A)
Home
Find... Go To..
SOLUTION
Turn switch ON.
Contact Service Center.
Contact Service Center.
Contact Service Center.
Reset circuit breaker and change
to different power circuit.
Find air obstruction. Let motor
cool for 20 minutes.
Determine what caused breaker to
trip then reset breaker.
Replace bag.
Remove obstruction.
Contact Service Center.
Replace gasket.
Adjust brush height.
Remove clogged material.
See MACHINE MAINTENANCE;
Brush and Belt.
Contact Service Center.
3260
48cm
66cm
112cm
20.5 Kg
230V, 0.15kW/0.2 hp,.5 A, 1.800 rpm
230V, 1.12 kW/1.5 hp. 3.9 A
15m Gauge–18/3
61cm
10 L
70dB(A)
3240/3260 (02–01)

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

3260611368611369

Tabla de contenido