NINFA 24 MCS
Burner pressure adjustment
Since this unit has flame modulation, there are two fixed pressure values: the minimum and maximum, which must be
those given in the technical data table according to the type of gas.
Connect a suitable pressure gauge to the pressure point "B" located downstream of the gas valve.
Disconnect the pressure compensation tube "H".
Remove the protection cap "D".
Operate the boiler in TEST mode, turning the selector to TEST.
Adjust the maximum pressure with the screw "G", turning it clockwise to increase and anticlockwise to decrease the
pressure.
Disconnect one of the two faston connectors from the modureg "C" on the gas valve.
Adjust the minimum pressure with the screw "E", turning it clockwise to decrease and anticlockwise to increase the
pressure.
Refit the faston connector removed from the modureg on the gas valve.
Make sure the maximum pressure has not changed.
Reconnect the pressure compensation tube "H".
Refit the protection cap "D".
To end TEST mode, turn the selector to a different position from TEST or wait 15 minutes.
After checking or adjusting the pressure, make sure to seal the adjustment screw with paint or a spe-
A
cific seal.
B
Pressure point downstream
E
Minimum pressure adjustment
H
Compensation tube
C
Modureg cable
G
Maximum pressure adjustment
D
Safety cap
Heating power adjustment
Refer to the Service Menu section.
Lighting power adjustment
Refer to the Service Menu section.
GB
fig. 25 - Gas valve
cod. 3540F611 - 05/2007 (Rev. 00)