7. Replace inlet valve assembly.
8. Assemble inlet fitting - torque to 160-180 in-lbs.
9. Add a few drops of piston lube inside the inlet valve
fitting, the return tube fitting and the outlet valve. This will
improve priming the next time the pump is used.
10. Store in a clean, dry area.
11. Wipe down tubes, hose, and gun.
12. Store pump in an upright position.
IMPORTaNT: Do not store inlet fitting and bypass/return
fitting immersed in hot solvents such as acetone, Lacquer
Thinner or MEk. If you wish to soak these fittings, immerse
in mineral spirits.
NOTE: To remove material build-up and prolong inlet/
outlet valve life, soak the valves in lacquer
thinner overnight periodically. This will loosen
up any accumulated material between the O-ring
and valve seat.
Maintenance
Follow all other warnings to reduce the risk of an
injection injury, injury from moving parts or electric
shock. always disconnect the pump before
servicing!
after every use
• Oil inlet valve, outlet valve, and quick connect fittings with
a few drops of Titan Piston Lube.
Monthly
• Remove heel cover. Lubricate crank components with
a few drops of Titan Piston Lube. Insert an 9/32 allen
wrench into the shoulder screw and rotate the eccentric to
draw oil into cracks. Do not use grease.
Shoulder
screw
Heel cover
Screw
English
General Repair and Service Notes
1. Before repairing any part of the Transfer Pump, read the
instructions carefully, including all warnings.
IMPORTaNT: Never pull on a wire to disconnect it. Pulling
on a wire could loosen the connector from the wire.
2. Test your repair before regular operation of the sprayer
to be sure that the problem is corrected. If the sprayer
does not operate properly, review the repair procedure to
determine if everything was done correctly. Refer to the
Troubleshooting section to help identify other possible
problems.
3. Make certain that the service area is well ventilated in
case solvents are used during cleaning. Always wear
protective eyewear while servicing. Additional protective
equipment may be required depending on the type of
cleaning solvent. Always contact the supplier of solvents
for recommendations.
4. If you have any further questions concerning your TITAN
airless pump, call TITAN:
Technical Service (U.S.) ....................... 1-800-526-5362
Technical Service (Canada) .................. 1-800-565-8665
Service
Replacing the Inlet valve
NOTE: The inlet valve in this pump will need to be
1. Perform CLEANUP procedure.
2. Adjust pressure to PRIME position.
3. Remove siphon and return tubes.
4. Remove material hose
5. Remove pump from turbine, ensuring power is removed.
6. Tip pump on its side to drain excess solvent. The unit
should be tipped on the side that contains the fittings for
the siphon/return tubes.
7. Remove inlet fitting.
8. Remove inlet valve assembly.
Oil
Oil
NOTE: To free the inlet valve assembly, gently rock the
9. Replace with new inlet valve assembly.
10. Assemble inlet fitting - torque to 160-180 in-lbs.
8
Fax ................................................ 1-800-528-4826
Fax ................................................. 1-800-856-8496
serviced approximately every 10-20 hours of run
time depending on media type and speed setting.
inlet valve assembly back and forth to free it from
the pump housing.
© Titan Tool. All rights reserved.
Inlet valve
Inlet fitting