Troubleshooting

Problem
A.
Pump will not run and green
light is out
B.
Pump will not run and green
light is on
C.
Pump runs but does not
prime.
D.
Pump primes and is returning
to the material container
through the bypass/return
tube, but nothing is coming
out of the gun.
E.
Spray pattern is too light.
F.
Spray pattern is too heavy
G.
Pulsating spray pattern while
using thin materials.
H.
Material is leaking on or from
the drip tray or cupholder.
English
cause
1.
Pump is not fully locked into turbine.
2.
Turbine is not plugged in.
3.
Fuse is blown in the pump.
4.
Faulty or loose wiring.
1.
Faulty motor.
2.
Faulty board.
1.
Inlet valve is stuck.
2.
Siphon tube is not fully inserted into the
inlet fitting.
3.
Siphon tube not fully immersed in the
spray material.
4.
Pressure setting knob not set to PRIME.
5.
Inlet fitting is not tightened properly.
6.
Quick-connect inlet fitting is damaged or
dirty.
7.
Inlet valve is worn or contains material
buildup.
8.
Siphon tube or filter is clogged.
9.
Faulty outlet valve.
1.
Pressure too low.
2.
Spray material is too thick.
3.
Pressure setting valve poppet and set are
worn.
1.
Gun not adjusted properly, or too small of
a projector set is being used.
2.
Pressure too low.
3.
Spray material is too thick.
1.
Pressure too high.
2.
Gun not adjusted properly.
1.
Pressure too low, too much needle travel
on the spray gun.
1.
Seal and piston are worn.
Solution
1.
Ensure there is not something binding under the
pump preventing it from fully seating and ensure
the connector cover has engaged (clicked over) the
locking tabs on the pump.
2.
Check turbine lighted cord, it should be lit. Plug in.
3.
Remove heel cover and lubricate eccentric (see
Service, Replacing the Seal and Piston section).
Replace the fuse. If it blows repeatedly, the seal
must be serviced immediately. Use only fuse type
specified in the Parts List. Using other types of fuse
may cause damage to the pump.
4.
Take your Transfer Pump to an authorized service
center.
1.
Replace the motor (see Service, Replacing the
Motor section).
2.
Replace the board.
1.
Remove siphon tube and depress inlet valve with
inlet valve tool (or some other long, slender tool).
2.
Fully insert and secure the siphon tube into the inlet
connection.
3.
Immerse the siphon tube into the spray material.
4.
Turn the pressure setting knob fully
counterclockwise.
5.
Tighten the inlet fitting to 160-180 in-lbs.
6.
Clean or replace.
7.
Replace the inlet valve (see Service, Replacing the
Inlet valve section).
8.
Clean the siphon tube and filter.
9.
Replace the outlet valve (see Service, Replacing
the Outlet valve section).
1.
Turn the pressure setting knob clockwise to increase.
2.
See recommended thinning section in spray gun
manual.
Replace (see Service, Replacing the Pressure
3.
Setting valve section).
1.
See spray gun manual for gun adjustment
procedures and projector set information.
2.
Turn the pressure setting knob clockwise to increase.
3.
See recommended thinning section in spray gun
manual.
1.
Turn the pressure setting knob counterclockwise to
decrease.
2.
See spray gun manual for gun adjustment
procedures.
1.
Increase pump pressure to 4 or 5, and decrease the
needle travel on the spray gun.
1.
Replace the piston and seal (see Service,
Replacing the Seal and Piston section).
12