Overheating protection 230 V
The 230 V heating facility has a mechanical overheating
switch. If the 12 V power supply is interrupted during opera-
tion or during the after-run period, for example, the tempera-
tures within the unit could activate the overheating protection.
To reset the overheating protection, allow heater to cool,
remove connection cover and press red reset button.
Disposal
The liquid gas heater must be disposed in accordance with
the administrative stipulations of the respective country in
which it is used. National regulations and laws (in Germany,
for example, the Altfahrzeug-Verordnung [old vehicle direc-
tive]) must be observed.
In other countries, the relevant regulations must be observed.

Technical data

determined in accordance with EN 624
or Truma test conditions
Device category
I
in accordance with EN 437
3 B/P
Type of gas
Liquid gas (propane / butane)
Operating pressure
30 mbar (see type plate)
Water contents
10 litres
Heating up time from approx. 15° C to approx. 60° C
Boiler approx. 20 minutes (measured according to EN 15033)
Heater + boiler approx. 80 min.
Water pressure
max. 2.8 bar
Rated thermal output (automatic output levels)
Gas operation
Combi 4 E: 2000 W / 4000 W
Combi 6 E: 2000 W / 4000 W / 6000 W
Electrical operation
Combi 4 E / Combi 6 E: 900 W / 1800 W
Mixed operation (gas and electrical)
Combi 4 E: max. 3800 W
Combi 6 E: max. 5800 W
Gas consumption
Combi 4 E: 160 – 320 g/h
Combi 6 E: 160 – 480 g/h
Readiness-heat power requirement Combi 4 E / Combi 6 E:
Gas operation 5.2 g/h
Air delivery volume (free-blowing without hot-air pipe)
Combi 4 E: with 3 hot-air outlets max. 249 m³/h
with 4 hot-air outlets max. 287 m³/h
Combi 6 E: with 4 hot-air outlets max. 287 m³/h
Current input at 12 V
Heater + boiler
Combi 4 E: Short-term max. 5.6 A
(average power consumption 1.1 A)
Combi 6 E: Short-term max. 5.6 A
(average power consumption 1.3 A)
Heating up of boiler: 0.4 A
Stand-by: 0.001 A
Heating element FrostControl (optional): maximum 0.4 A
Current input of 230 V
3.9 A (900 W) or 7.8 A (1800 W)
Weight (without water contents)
15.6 kg
Declaration of conformity
The Truma Combi E has been tested by the DVGW and com-
plies with the gas equipment directive (90/396/EEC) and the
other applicable EC directives. The following CE Product
Ident. No. is available for EU countries
Combi 4 E / Combi 6 E: CE-0085BS0085.
The heater complies with heater directive 2001/56/EC and
supplements 2004/78/EC and 2006/119/EC and bears the type
approval number
Combi 4 E: e1 00 0193
Combi 6 E: e1 00 0194.
The heater complies with the interference suppression
directive 72/245/EEC for vehicle engines with annexes
2004/104/EC, 2005/83/EC and 2006/28/EC and bears type
approval number: e1 03 5020.
The heater complies with EMC directive 89/336/EEC and low
voltage directive 73/23/EEC.
The right to effect technical modifications is reserved!
Dimensions
450 mm
510 mm
15

Hide quick links:

Publicidad

loading

Este manual también es adecuado para:

Combi 6 e