Messages Shown On The Display; Error Messages - Dea NET24N Instrucciones De Uso

Ocultar thumbs Ver también para NET24N:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 123

8 MESSAGES SHOWN ON THE DISPLAY

Mess.
Gate is closed
Gate is opened
Opening under way
Closing under way
While in step-by-step mode, the control board awaits further instructions after a start command
Stop input intervened or an obstacle is detected with limited inversion duration (P055 > 0 or P056 > 0)
Board in BOOT-MODE: Indicates that the firmware is corrupted or updating. To restore the firmware, use the DEAinstaller APP and make sure
NET-NODE is corrected to the correct port.
Warning: When updating the firmware, all data in the board memory (settings and radio commands) are lost. Make sure you have backed
up the memory to be restore data after the update.
Reset current position: The control unit has just been turned on after a power failure, or the gate has exceeded the maximum number (80) of
inversions allowed without ever getting to the closing stroke, or the maximum number (7) of consecutive operations allowed of the anti- crushing
device.
Once the control unit has been reset and open command given the gate will start moving at slow speed, until it reaches end of travel.
Mess.
Error position: The reset position procedure is not suc-
cessful. The control panel is awaiting commands.
Board programming attempted when a NET-NODE
device is connected.
External photocells and/or safety devices are activated
or out of order.
Possible fault/overheating in the control unit's power
circuit.
Time-out operators run: The engine/s exceeded the
maximum operating time (4min) without ever stopping.
Time-out obstacle detection: With anti-crushing sensor
disabled, was still detected the presence of an obsta-
cle that prevents movement of the leaf for a period of
10 seconds more.
Operators mouvement not detected.
No/interrupted communication with remote memory
board (also NET-EXP or NET-NODE).
Possible fault/overheating in the control unit's power
circuit.
Possible malfunction in the control unit's power circuit
or in the encoder circuit.
NET-NODE connected to the incorrect communication
port.
48
WORKING STATUS MESSAGES

ERROR MESSAGES

Description
- Make sure there are no specific frictions and / or obstacles during the run;
- Give a start pulse to initiate a position reset procedure;
- Verify that the operation is completed successfully, manually helping the run, if ne-
cessary;
- Adjust power and speed settings if necessary.
Turn off power, disconnect the NET-NODE from the communication port and turn back
on;
- Make sure that all safety devices and/or photocells installed are working properly.
Turn off power for several minutes and turn back on. Give a start command: if the
message is repeated, replace the control unit.
- Give a start pulse to start the position reset procedure;
- Ensure that this operation is successful.
- Make sure there are no specific frictions and / or obstacles during the run;
- Give a start pulse to initiate a position reset procedure;
- Verify that the operation is completed successfully.
- Make sure that operators and encoders connections are well done.
- Check that jumpers J5 and J9 are well positioned as shown on the electric wiring.
- If this error appears again, replace the control panel.
- Check that the connecting cable of the external memory card is connected properly.
- If you are performing a data transfer operation (DOWNLOAD / UPLOAD), make sure
that it is not interrupted (eg by unplugging the card before the end of the operation).
Please note: the interruption of an UPLOAD, also involves a total RESET of the control
unit.
Turn off power for several minutes and turn back on. Give a start command: if the
message is repeated, replace the control unit.
Check the wiring of the encoder and the motor. Shut the power supply off and on again.
Give a start command: if the message is repeated, perform the following checks.
- Enter P003 and move the door using the + and - buttons.
- If the door moves at maximum speed and the display shows Err7, replace the motor's
encoder card.
- If the motor still remains stationary, replace the control unit.
Connect NET-NODE to the correct port according to that indicated in the control unit
diagram.
Description
Possible solutions

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido