Fix the air outlet adaptor onto the cooker hood, then install the cooker hood on the bottom of
the hanging cupboard, tighten the 4 screws (supplied).
as shown in below photo
When installed the distance between the hood and the hob must be not less than 65 cm
above an electric hob or 75 cm above a gas or mixed fuel hob. This hood must not be fitted
above an eye level grill cooker without checking with the cooker's manufacture as it might
adversely affect the functioning of the grill. If the room where the cooker hood is fitted
contains a fuel burning appliance (such as central heating) its flue should be of the balanced
Flue type. If other types of flue are fitted ensure that a sufficient supply of air to the room is
available. The air must not be discharged into a flue that is used for exhausting fumes from
appliances burning gas or other fuels.
WARNING: Check that there are no water pipes or electrical cables in the wall where you
want to mount the hood before drilling any holes.
OPERATION
To open the Hood, push the two clips inwards and the filter cover will drop down.
7