Quick BXS 25 Manual Del Usuario página 13

Ocultar thumbs Ver también para BXS 25:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

WARNING:
follow the instructions of the boat engine manufacturer on how to connect en-
gine cooling liquid to the heat exchanger.
• Fit the stub pipe (7) to the valve (5) using hose clamp. Fit the pipe so as to allow any possible
water leak not to cause damage to part of the boat.
• Open up hot water taps of washbasins and start the water pump. This allows water to fill water
heater and force air out of water heater and pipes. Close taps as soon as air free water comes out.
• check that there are no leaks on pipe joints.
UNIT POWER SUPPLY
The unit has been already provided with power supply cable for AC current. Make sure the water
heater working voltage is the same as that provided from AC network.
A double pole switch has to be included on the electric installation, in order to turn on and off the
unit, and a fuse of suitable rating. The insulation between connections contacts of the AC network
must be at least 3 mm. The connections to AC network must be done following the National Specifi-
cations on electrical installations.
WARNING:
make sure there is no power into the cable before making connection.
WARNING:
in case the power supply cable is damaged, ensure it is replaced by a QUICK ser-
vice center. In order to avoid accidents, the equipment has to be opened by authorized per-
sonnel only. If opened by an unauthorized person, the warranty is considered not to be valid.
WARNING:
cause a permanent damage to the electric element.
THERMOSTAT ADJUSTING
The standard temperature value of the thermostat is 60°C. If you wish to change it, follow the instruc-
tions below:
• shut down power supply.
• Remove the protection cover (12) in order to reach the thermostat (10).
• Adjust the thermostat knob with a screwdriver (fig. 4) and turn it to the required temperature.
• Replace on the protection cover (12).
• Switch on power supply.
The mixer controls the hot water temperature when the heating elements and the heat ex-
changer are used.
(In model provided with)
don't operate the electric element if the tank is not filled with water. It may
(in model provided with)
USAGE
GB
13