6 TROUBLESHOOTING
The repair or replacement of any parts in the
system must be carried out only by qualified
personnel.
The repair or replacement of any parts in the system by unau-
thorised personnel will invalidate the product warranty.
The system must not be modified in any way.
The manufacturer disclaims any responsibility if the user
fails to follow these instructions.
The system fails to come on (green LED off)
Cause
No mains voltage at the socket.
Solution
Check and repair the electrical system as needed.
Use qualified personnel only.
Cause
Faulty plug or cable.
Solution
Replace the faulty component.
Contact the nearest service centre to have the sys-
tem repaired.
Cause
Line fuse blown.
Solution
Replace the faulty component.
Cause
Faulty on/off switch.
Solution
Replace the faulty component.
Contact the nearest service centre to have the sys-
tem repaired.
Cause
Faulty electronics.
Solution
Contact the nearest service centre to have the sys-
tem repaired.
No output power
Cause
Faulty torch trigger button.
Solution
Replace the faulty component.
Contact the nearest service centre to have the sys-
tem repaired.
Cause
The system has overheated (temperature alarm -
yellow LED on).
Solution
Wait for the system to cool down without switching
it off.
24
7.
Remove the cable clamp
and gusset (H).
8.
Pull out the torch from the
outside (I).
Cause
Incorrect earth connection.
Solution
Earth the system correctly.
Read the paragraph "Installation ".
Cause
Mains voltage out of range (yellow LED on).
Solution
Bring the mains voltage within the power source
admissible range.
Connect the system correctly.
Read the paragraph "Connections ".
Cause
Faulty electronics.
Solution
Contact the nearest service centre to have the sys-
tem repaired.
Incorrect output power
Cause
Faulty potentiometer for the adjustment of the cut-
ting current.
Solution
Replace the faulty component.
Contact the nearest service centre to have the sys-
tem repaired.
Cause
Faulty electronics.
Solution
Contact the nearest service centre to have the sys-
tem repaired.
No pilot arc striking
Cause
Faulty torch trigger button.
Solution
Replace the faulty component.
Contact the nearest service centre to have the sys-
tem repaired.
Cause
Worn nozzle and/or electrode.
Solution
Replace the faulty component.
Cause
Air pressure too high.
Solution
Adjust the air flow.
Read the paragraph "Installation".
Cause
Faulty electronics.
Solution
Contact the nearest service centre to have the sys-
tem repaired.
No cutting arc striking
Cause
Incorrect earth connection.
Solution
Earth the system correctly
Read the paragraph "Installation".
Cutting arc extinction
Cause
Mains voltage out of range.
Solution
Connect the system correctly.
Read the paragraph "Connections".
Cause
Insufficient air flow rate.
Solution
Adjust the air flow.
Cause
Damaged pressure switch.
Solution
Replace the faulty component.
Cause
Air pressure too high.
Solution
Adjust the air flow.
Read the paragraph "Installation".
Cause
Incorrect cutting mode.
Solution
Decrease the cutting travel speed.
Cause
Worn nozzle and/or electrode.
Solution
Replace the faulty component.