Connector Configuration
Connection to the Mains
Connect the supplied power supply cable to the correspond-
ing input and the mains plaug to an outlet (AC 230 V, 50 Hz).
The mixer can also be operated with AC 115V, 60 Hz --. For this
purpose, set the voltage selector switch to the 115 V position.
The occupation of the connection cables is as follows:
The earth has to be connected! If the device will be directly
connect with the local power supply network, a disconnec-
tion switch with a minimum opening of 3mm at every pole
has to be included in the permanent electrical installation.
The device must only be connected with an electric instal-
lation carried out in compliance with the IEC standards. The
electric installation must be equipped with a Residual Cur-
rent Device (RCD) with a maximum fault current of 30mA.